        1. Prepare Whatman DE-52 according to manufacturers specifications. Equilibrate at store with 0.02% Sodium azide.

        2. Plug a 1 mL (blue) pipet tip with Siliconized glass wool. Add 500 ml of 50:50 DE-52 slurry. Pack into a 250 mL column by gently forcing the fluid through with a P-1000 pipetter.

        3. Rinse column twice with 1 mL TE, forcing through with a P-1000.

        4. Add 200 ml TE to Kinased Oligo. Apply the solution to the column and gently force though with the P-1000.

        5. Elute nucleotides by washing 4 times with 1 mL 0.2 M NaCL in TE. Monitor counts removed. Most residual ATP should be removed after the first 2 rinses.

        6. Elute the labeled oligonucleotide with 500 ml 1 M NaCl in TE. Repeat 3 times, collecting each rinse separately. The first rinse should contain most of the oligonucleotide.

        7. Up to 10% of the counts may remain on the column.