产品封面图

Quantus™ Fluorometer

收藏
  • 询价
  • promega
  • 美国
  • E6150
  • 2025年07月13日
    • 详细信息
    • 询价记录
    • 文献和实验
    • 技术资料
    • 库存

      N

    • 供应商

      上海梦泽生物科技有限公司

    • 现货状态

      现货

    • 保修期

      1年

    Highly sensitive, affordable, single-tube fluorometer

    The Quantus™ Fluorometer is a compact, dual-channel fluorometer designed to provide highly sensitive fluorescent detection when quantifying nucleic acids. The Quantus™ Fluorometer is optimized with preprogrammed settings for Promega QuantiFluor® Dye Systems (QuantiFluor® dsDNA, RNA and ssDNA Systems) to quantitate nucleic acids and offers the flexibility to create customized methods and quantitation settings for other fluorescent dyes.



    Features

    • Easy, intuitive controls.
    • Calculates concentration automatically.
    • Store the last 50 readings and transfer data in real time.
    • Recommended for NGS and compatible with Illumina (HiSeq/miSeq), Roche (454) and LifeTech (ion Torrent and ion Proton) Systems.

    Two fluorescent channels: 
    • Red: Ex: 640nm shortpass (wavelengths up to 640nm); Em: 660–720nm
    • Blue: Ex: 495nm shortpass (wavelengths up to 495nm); Em: 510–580nm

    Easily customize sample names, view concentration results, raw values, sample volumes and a quality checkCompact size at only 22.7 x 11.5 x 4Large 3-inch liquid crystal display screen

    Intuitive navigation

    Performance

    Detection Sensitivity

    Fluorescence-based nucleic acid quantification methods are more sensitive than absorbance-based methods, allowing you to quantitate low-level DNA samples accurately.

    Custom protocols can be created for the Quantus™ Fluorometer to detect even lower amounts.

    Broad Dynamic Range

    Complement your absorbance-based methods and quantify your target molecule over a wider range of concentrations. 

    Quantitation of more dilute samples is possible using more input dsDNA per assay.

    Calibration & Sample Measurement

    The calibration process eliminates the need to generate a standard curve for each set of unknown samples. Simply measure the fluorescence of your blank sample and the standard that represents the highest point on your standard curve. The Quantus™ Fluorometer saves the calibration data for future measurements.

    No computer is necessary to use the Quantus™ Fluorometer, but after installing the free Quantus™ Software you can automatically transfer your quantitation results from the Quantus™ Fluorometer to a personal computer in real time. Export results easily into Microsoft® Excel.
     

    Design Features

    Size 22.7 × 11.5 × 4.5cm (L × W × H)
    Weight 400 grams
    Linear Dynamic Range Five orders of magnitude, assay-dependent
    Detectors Solid state silicon sensor
    Excitation Filters Red: 640nm shortpass (wavelengths up to 640nm)
    Blue: 495nm shortpass (wavelengths up to 495nm)
    Emission Filters Red: 660–720nm
    Blue: 510–580nm
    Calibration Type Single-point (blank and standard)
    Sample Tube We recommend Axygen thin-walled PCR tubes (Axygen Cat.# PCR-05-C, available from Fisher or VWR)
    Automatic Sleep Mode After 1 hour of inactivity
    Power Requirements 5V, 0.2A Maximum
    Operating System Requirements 
    (for optional Quantus™ Software)
    Windows® 8, Windows® 7 (32 or 64 bit) .NET Framework 4.0 or later At least one USB port available

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    • 作者
    • 内容
    • 询问日期
    图标文献和实验
    相关实验
    • 寻找KO的阳性克隆——Cruiser

      近年来,ZFN、TALEN、CRISPR/Cas9等基因组编辑技术可谓是层出不穷,尤其是CRISPR/Cas9,一出现便在全球范围内掀起一股热潮。同时,各大公司也开发出一系列相应的产品,其中一种至关重要的就是基因敲除阳性克隆筛选的试剂。 目前,市面上只有Genloci的Cruiser、Transgenomic的SURVEYOR和NEB的T7EI这三种产品和测序这种方法,被用于基因敲除阳性克隆的筛选。然而,SURVEYOR是进口产品,价格贵,货期长;T7EI可以识别多种DNA结构,如十字

    • NEB 发布:GenomONE 为诱导 iPSC 形成「保驾护航」

      间充质干细胞(MSC, mesenchymal stem cells)是干细胞家族的重要成员,属于多能干细胞,因其具有多向分化潜能、造血支持和促进干细胞植入、免疫调控和自我复制等特点而日益受到人们的关注。诱导性多能性的间充质干细胞(iPMSCs)是药物筛选、再生医学和细胞治疗的新型候选药物。然而,用于生成骨髓间充质干细胞的诱导性多能性间充质干细胞(iPSC),在导入编码基因的转录因子中,往往伴随有在靶细胞基因组的插入时发生突变的风险。 由于近年来对骨髓间充质干细胞认知地深入,在造血系统、免疫

    • Ratiometric Ca2+ Measurements Using the FlexStationScanning Fluorometer

      The FlexStation � Scanning Fluorometer is a fluorescence plate reader that can measure intracellular Ca2+ concentration using both single-wavelength and dual-wavelength fluorescent probes. The FlexStation uses a Xenon flashlamp

    图标技术资料

    需要更多技术资料 索取更多技术资料

    资料下载:

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    询价
    诺达思(北京)信息技术有限责任公司
    2026年01月14日询价
    询价
    上海赛弗生物科技有限公司
    2026年01月05日询价
    $10000
    北京普升达科贸有限公司
    2026年01月13日询价
    询价
    美国健康医疗仪器国际公司
    2026年01月14日询价
    Quantus™ Fluorometer
    询价