相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 英文名:
TransIT®-mRNA Transfection Kit
- 供应商:
MIR2250
- 库存:
MIR2250
- 规格:
1ml/kit
TransIT®-mRNA Transfection Kit
TransIT®-mRNA Transfection Kit TransIT®-mRNA转染试剂盒(包含mRNA转染试剂和转染增强辅助试剂,可满足大分子量RNA的高效转染,适用于病毒包装、蛋白表达和CRISPR基因编辑等) (MIR2250 )
每个试剂盒均配有TransIT®-信使核糖核酸转染试剂和信使核糖核酸增强试剂
低细胞毒性-保持细胞密度并减少实验偏差
高效递送-在大量细胞中实现RNA递送,确保实验成功
血清相容性–在血清存在的情况下进行转染,无需更换培养基并保持细胞健康
提供各种大小的RNA——非常适合特殊应用,如病毒生产、蛋白质表达和CRISPR基因组编辑
Figures and Data
Efficient Genome Editing with Cas9 mRNA + Guide RNA Oligonucleotides. HEK293T/17, U2OS and NHDF cells were co-transfected with 0.5 µg of Cas9 encoding mRNA, 5meC, ψ (Trilink Biotechnologies) and 25nM of PPIB targeting 2-part gRNA (Dharmacon) using TransIT®-mRNA Transfection Kit (0.5 µl/well of 24-well plate of both mRNA Reagent and Boost, Mirus Bio). A T7E1 mismatch detection assay was used to measure cleavage efficiency at 48 hours post-transfection.
High Efficiency and Low Toxicity Transfection Following 14 Consecutive Transfections with TransIT®-mRNA Transfection Kit. Repeated daily transfections were performed in the same population of BJ fibroblasts using TransIT®-mRNA Transfection Kit, Lipofectamine® RNAiMAX (Life Technologies) and Stemfect™ RNA Transfection Kit (Stemgent) - with a capped and polyadenylated EGFP mRNA incorporating pseudouridine and 5mC modified bases (Trilink Biotechnologies, Inc.). Multiple reagent-to-RNA ratios were tested and the optimal ratio is represented. Transfections were performed in 12-well plates using the indicated reagent-to-RNA ratios to deliver 1 µg of RNA. GFP and phase contrast images were taken in the same field of view everyday after transfection. Transfection efficiency was measured by flow cytometry on a Guava® easyCyte™ 5HT following 14 consecutive daily transfections (blue bars). Cell viability was determined using cell counts measured during flow cytometry (black line grey bars). Error bars represent the standard deviation of triplicate wells.
TransIT®-mRNA Transfection Kit Transfects GFP mRNA into DC 2.4 Dendritic Cells. Using TransIT®-mRNA Transfection Kit, DC 2.4 cells were transfected with (A) 0.5 µg, (B) 1 µg and (C) 2.5 µg of capped and polyadenylated mRNA encoding GFP with 1 µl TransIT®-mRNA Reagent and 1 µl Boost. Cells were seeded overnight at 100,000 cells/well in 24-well plates. Images were taken 10 hours post-transfection.
Data courtesy of Kyle Phua (Principal Investigator: Kam W. Leong), Duke University
Multiple Dendritic Cell Types Express GFP from mRNA Transfected by TransIT®-mRNA Transfection Kit. Murine primary bone marrow derived dendritic cells (BMDC) and murine dendritic cells types (JAWSII and DC 2.4) were transfected with 1 µg of capped and polyadenlyated mRNA encoding GFP using a TransIT®-mRNA Reagent: Boost: mRNA ratio of 1:1:1 (µl:µl:µg). Primary BMDCs, JAWSII and DC 2.4 were seeded (80,000 cell/well) overnight in 24-well plates. Cells were assayed via flow cytometry 8 hours post transfection. Error bars represent the standard deviation of at least 3 separate experiments.
Data courtesy of Kyle Phua (Principal Investigator: Kam W. Leong), Duke University
High Level Luciferase Expression after Delivery of a Luciferase mRNA Using TransIT®-mRNA Transfection Kit. Cells in 12-well plates were transfected with a capped and polyadenylated mRNA encoding luciferase using the TransIT®-mRNA Transfection Kit. Approximately 18 hrs post-transfection the cells were harvested and the total luciferase activity per well was determined.
TransIT®-mRNA Transfection Kit Efficiently Delivers lacZ mRNA to CHO-K1 Cells. Using the TransIT®-mRNA Transfection Kit, CHO-K1 cells were mock transfected (A) or transfected with a capped and polyadenylated lacZ encoding mRNA (B). Approximately 18 hrs post-transfection the cells were stained using Mirus Bio’s Beta-gal Staining Kit to identify the lacZ transfected cells.
Transfection Optimization in Sf9 insect cells with TransIT®-mRNA Transfection Kit. Mixed adherent and suspension Sf9 insect cells were transfected in a 12-well plate with CleanCap EGFP mRNA (TriLink BioTechnologies). TransIT®-mRNA complexes were prepared in Grace’s Insect Medium (Thermo Fisher Scientific) with different ratios of TransIT®-mRNA Transfection Reagent, mRNA Boost Reagent, and EGFP mRNA (v:v:w). All transfection complexes were incubated for 5 min at room temperature. The best ratio identified was 4 µl TransIT®-mRNA : 4 µl mRNA Boost : 2 µg EGFP mRNA (1 µg/µl); representative images were taken 18 hours post-transfection and are shown above.
Data courtesy of Valeriya Steffey, M.D. (Director, In-Vitro Studies), Hera BioLabs
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验樊小乖 请教各位高手,我要用质粒转染人支气管上皮细胞,用哪个试剂盒比较好,请指点一下 zhujoker 不知道你是使用得细胞株还是原代的,不同情况不同处理 樊小乖 是传代细胞 本文由丁香园论坛提供,想了解更多有用的、有意思的前沿资讯以及酷炫的实验方法的你,都可以成为师兄的好伙伴 师兄微信号:shixiongcoming
效率与温和之间的最佳平衡——Lipofectamine® LTX 强壮的细胞系自不必说,L2K便是很好的选择。但对于某些对转染试剂 敏感的细胞系,L2K的毒性也是无法回避的问题。于是,Invitrogen推出了毒性较低的Lipofectamine® LTX。这也意味着在获得高转染效率和高蛋白表达的同时,无需担心转染后细胞的活力。 当然,转染效率也是大家首要考量的因素,特别是在研究原代细胞、神经细胞和干细胞 这些难对付的细胞时。当然,Invitrogen也考虑
,Lipofectamine® LTX试剂不能用于小分子RNA的转染 ,这一点与L2K可不同。因此,在选择质粒与RNA的共转染试剂时,还须选择L2K。 还有一个好消息!以往,Invitrogen的转染试剂只有0.75 ml/1 ml的包装。对于某些不经常做转染,或者只想试一下的客户来说,这个包装太大了,于是他们便改投了Fugene的怀抱。Invitrogen当然也意识到了这个问题,不久前推出了0.1 ml的Lipofectamine® LTX & PLUS小包装,价格约为528元。常规的1 ml包装
技术资料暂无技术资料 索取技术资料








