Soluble Glucoprotein 130 ELISA

Kit (sGP130), Human
收藏
  • $975
  • KAMIYA BIOMEDICAL COMPANY
  • 详见说明书
  • 美国加利福尼
  • 2025年07月14日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 文献和实验
    • 技术资料
    • 样本

      血清、血浆、尿液、组织、上清液

    • 库存

      60

    • 标记物

      详见官方网站

    • 适应物种

      Human

    • 应用

      ELISA

    • 检测方法

      酶联免疫方法

    • 检测范围

      详见说明书

    • 供应商

      钰博生物

    • 规格

      96 tests

    Soluble Glucoprotein 130 ELISA Kit (sGP130), Human
     
    For quantitative detection in human samples.  (no photo available) 96 tests $975 KT-66153

    COMPONENTS
    Reagents Quantity
    Pre-coated, ready to use 96-well strip plate 1
    Calibrator 2
    Calibrator Diluent 1 × 20 mL
    Detection Reagent A 1 × 120 uL
    Detection Reagent B 1 × 120 uL
    Assay Diluent A 1 × 12 mL
    Assay Diluent B 1 × 12 mL
    TMB Substrate 1 × 9 mL
    Stop Solution 1 × 6 mL
    Wash Buffer (30X concentrate) 1 × 20 mL
    Plate sealer for 96 wells 4
    MATERIALS REQUIRED BUT NOT SUPPLIED
    1. Microplate reader with 450 ± 10 nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.a
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution. STORAGE All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon being received while the others should be at 4°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable for 1 month, provided it is stored as prescribed above.
    SAMPLE COLLECTION AND STORAGE
    Plasma
    Collect plasma using 3.8% sodium citrate (sodium citrate:blood = 1:9) as an anticoagulant. Centrifuge samples for 15 minutes at 1000 × g at 4°C within 30 minutes of collection. Remove plasma and assay immediately or store
    samples in aliquot at -20°C or -80°C for later use. Avoid repeated freeze/thaw cycles. Note:
    1. Samples to be used within 5 days may be stored at 4°C, otherwise samples must be stored at -20°C (≤1 month) or -80°C (≤2 months) to avoid loss of bioactivity and contamination.
    2. When performing the assay slowly bring samples to room temperature. 3. Sample hemolysis will influence the result, so hemolytic specimen can not be detected.
    REAGENT PREPARATION
    Bring all kit components and samples to room temperature (18-25°C) before use.
    产品细节图片1
    Detection Reagent A and B
    Briefly spin or centrifuge the stock Detection Reagent A and Detection Reagent B before use. Dilute to the working concentration with Assay Diluent A or B, respectively (1:100).
    Wash Solution
    Dilute 20 mL of Wash Solution concentrate (30X) with 580 mL of de-ionized or distilled water to prepare 600 mL of Wash Solution (1X).
    ASSAY PROCEDURE SUMMARY
    1. Prepare all reagents, samples and calibrators;
    2. Add 100 µL calibrator or sample to each well. Incubate 2 hours at 37°C;
    3. Add 100 µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100 µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 90 µL Substrate Solution. Incubate 15-25 minutes at 37°C;
    8. Add 50 µL Stop Solution. Read at 450 nm immediately.
    IMPORTANT NOTES
    1. The final experimental results will be closely related to operation skills of the end users and theexperimental environments. Please make sure that sufficient samples are available.
    2. Kits from different batches may be a little different in detection range, sensitivity and color developingtime. Please perform the experiment exactly according to the instruction attached in kit whileelectronic ones from our website (www.k-assay.com) is only for information.
    3. Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied bymanufacturer.
    4. Protect all reagents from strong light during storage and incubation. All the bottle caps of reagentsshould be covered tightly to prevent the evaporation and contamination of microorganism.
    5. There may be some foggy substance in the wells when the plate is opened at the first time. It will nothave any effect on the final assay results. Do not remove microtiter plate from the storage bag untilneeded.
    6. Wrong operations during the reagents preparation and loading, as well as incorrect parameter settingfor the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10 nmor less and an optical density range of 0-3 O.D. or greater at 450 ± 10 nm wavelength is acceptablefor use in absorbance measurement. Please read the instruction carefully and adjust the instrumentprior to the experiment.
    7. Even the same operator might get different results in two separate experiments. In order to get betterreproducible results, the operation of every step in the assay should be controlled. Furthermore, apreliminary experiment before assay for each batch is recommended.
    8. Each kit has been strictly passed Q.C. test. However, results from end users might be inconsistentwith our in-house data due to some unexpected transportation conditions or different lab equipments.
    Intra-assay variance among kits from different batches might arise from above factors, too.
    9. Kits from different manufacturers for the same item might produce different results, since we haven’tcompared our products with other manufacturers.
    10. The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, andclothing protection when using this material.
     

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • 组织解离的常见问题及答案

      Perfusion Kit, mouse and rat,130-128-030) 搭配gentleMACS Octo八通道带加热全自动组织解离器使用。   7. 如何得到心肌细胞? 小鼠心脏由多种类型细胞构成,包括心肌细胞、成纤维细胞、内皮细胞、免疫细胞、平滑肌细胞等。其中心肌细胞通过闰盘紧密连接,需要较强的酶解,但细胞膜脆弱,很容易在解离过程中破裂而造成细胞死亡。尤其是成年小鼠心肌细胞,体积大且不规则,更加大分离难度。 对于新生小鼠,闰盘未完全成熟,细胞连接没有十分紧密,可以使用常规解离方法,但可能出现得率

    • 【分享】Human press METHODS IN MOLECULAR BIOLOGY

      9. Protocols in Human Molecular Genetics. Edited by G. Methaw, 1991 10. Immunochemical Protocols. Edited by Manson, Margaret M., 1992 11. Practical Protein Chromatography Edited by Kenney, Andrew, 1992 12. Pulsed-Field Gel Electrophoresis Protocols

    • MicroRNA Expression Profiling by Bead Array Technology in Human Tumor Cell Lines Treated with Interferon-Alpha-2a

      Assay (Invitrogen) as suggested by Illumina. Illumina Bead Array MicroRNA Detection Starting with 500 ng/sample of total RNA, mature microRNAs were amplified with the Illumina human v1 MicroRNA expression profiling kit containing primers for 743

    图标技术资料

    暂无技术资料 索取技术资料

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    询价
    上海禾午生物科技有限公司
    2025年05月09日询价
    询价
    上海抚生实业有限公司
    2025年07月15日询价
    询价
    上海西格生物科技有限公司
    2025年06月09日询价
    询价
    上海博湖生物科技有限公司
    2025年07月04日询价
    Soluble Glucoprotein 130 ELISA Kit (sGP130), Human
    $975