Maxprep™ Liquid Handler with t
he Maxwell® RSC 48 Instrument- 询价
- Promega
- 美国
- AS9100
- 2025年07月16日
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 询价记录
- 文献和实验
- 技术资料
- 库存:
N
- 供应商:
上海梦泽生物科技有限公司
- 现货状态:
45天
- 保修期:
1年
Nucleic Acid Purification System
Our modular nucleic acid preparation solutions let you adapt your laboratory workflow as your needs change. You can combine the Maxprep™ Liquid Handler with the Maxwell® RSC and RSC 48 Instruments for automated sample preparation to create a virtual assembly line in your laboratory.
The Maxprep™ Liquid Handler Comes With All the Methods Provided
From sample preprocessing to post-purification applications, the Maxprep™ Liquid Handler easily integrates wherever you need it in your laboratory workflow.
No Need to Waste Time with Programming
The Maxprep™ Liquid Handler comes with all the methods preloaded. The easy-to-use software interface means anyone in your lab will be able to quickly run samples using the preprogrammed protocols, and that means no methods to create or protocols to write.
Simplified Sample Preprocessing
The Maxprep™ Liquid Handler easily integrates wherever you need it in your laboratory workflow with preloaded methods for processing samples for nucleic acid extraction with your Maxwell® RSC or RSC 48 Instrument as well as preparing extracted samples for downstream applications such as amplification reactions, the Maxprep™ Liquid Handler ensures that every sample is handled the same way every time.
Intuitive Post-Extraction Protocols
After nucleic acid purification on your Maxwell® RSC Instruments, use the preloaded post-extraction methods on the Maxprep™ Liquid Handler for nucleic acid quantitation, dye addition, normalization, eluate transfers and amplification reaction setup.
The Maxwell® RSC Instruments Give You Flexible, Automated Nucleic Acid Purification
The Maxwell® RSC 48 Instrument works with a variety of sample types, including human blood, cells and tissues. With fast and easy protocols, prefilled cartridges and preprogrammed methods, you get reliable and consistent nucleic acid purification with the flexibility to process only the sample number you need. You can process anywhere from 1 to 48 samples with the Maxwell® RSC 48 Instrument.
Add Automated Sample Processing to Your Maxwell® RSC Instrument Workflow
The Maxprep™ Instrument works with the Maxwell® RSC Instruments you already have in your lab.
Reliable
Using prefilled cartridges and preprogrammed methods reduces the potential for user error. Purified nucleic acids are compatible with a wide range of downstream applications such as PCR, qPCR, Sanger and next generation sequencing (NGS), micro arrays and digital PCR.
Efficient
Automating nucleic acid extraction frees up your time. The integrated quantitation eliminates the need to re-enter sample IDs and creates a streamlined, simple sample tracking report that easily exports to your laboratory notebook.
Intuitive
Maxwell® RSC software is so easy to use and intuitive that you’ll be able to set up and perform your first run in a matter of minutes after initial instrument setup.
Confident
The large LED Indicator provides visual run status and an integrated vision system on the Maxwell® RSC 48 Instrument detects proper cartridge setup and further reduces the potential for user error.
Keep Track of Your Samples through Every Step
Create a virtual purification assembly line, preparing Maxwell® cartridges on the Maxprep™ Liquid Handler and purifying them using your Maxwell® RSC Instruments. You can place your instruments anywhere in the laboratory and sample tracking information will be communicated from one device to the next. Simply transfer the Maxwell® RSC deck tray from one instrument to the next and all the sample information will be there ready for you to process.
Sample Tracking
The Maxprep™ Liquid Handler automatically scans the sample bar codes as they are placed into the instrument. Once you scan the desired Maxwell® RCS Kit and the bar code on the Maxwell® Deck Trays, the Promega Portal software does the rest. Portal monitors where each sample is placed in the Deck Tray, what Maxwell® kit was used, and passes this information directly to the Maxwell® RSC or RSC 48 Instrument for walk-up extraction.
Increased Traceability
The Promega Portal software tracks samples as they move from one module to the next. The Portal software automatically shares sample IDs and recommends protocols for next steps as you move from one module to the next.
Service and Support
Our instruments are backed by a comprehensive standard warranty, expert service and a full line of additional service products. With a comprehensive menu of service and support options, you can be confident that your equipment will be working properly and ready when you need it. Installation Qualification (IQ), Operational Qualification (OQ) and Preventive Maintenance (PM) services ensure that your instrument is fully functional and provide documentation that the instrument is operating to defined specifications.
The Maxprep™ Liquid Handler is installed by qualified Promega personnel who will test the instrument, document installation actions and train lab personnel to successfully operate the instrument.
Instrument Specifications
Maxprep™ Liquid Handler
Sample Capacity: 1–48 Samples; (2) 24 position Maxwell® RSC 48 or (2) 16 position Maxwell® RSC removable trays
Intended Use: Research Use Only
Weight: 220 lbs (98.6 kg) est.
Dimensions (W × D × H): 42.1 × 27.8 × 33 inches (106.9 × 70.6 × 83.3 cm) Note: the total instrument height with the door open is 48.4inches (123cm)
Main Power Voltage: Input: 100–240VAC, 50/60Hz, 5A
Operating Environment: 15–25°C
Service and Warranty: 1-year limited warranty on parts and labor. Extended service contracts.
UV-Bulb: Average lifetime approximately 10,000 hours
Maxwell® RSC 48 Instrument
Sample Capacity: 1–48
Intended Use: Research Use Only
Weight: 60 lbs (27 kg) est.
Dimensions (W × D × H): 21 × 21 × 14 inches (53.3 × 53.3 × 35.6 cm) Note: the total instrument height excludes tablet PC
Main Power Voltage: Input: 100–240VAC, 50/60Hz, 5A
Operating Environment: 15–25°C
Service and Warranty: 1-year limited warranty on parts and labor. Extended service contracts.
UV-Bulb: Average lifetime approximately 9,000 hours
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
- 作者
- 内容
- 询问日期
文献和实验Mag-Bind Plant RNA Protocol using 96-well Plate
instrument, the starting material can be doubled to 30-40 mg. Double all the reagent volume in this protocol. 2. Immediately add 300 uL Buffer MRPL and 10 uL Proteinase K solution (25mg/ml). Seal the plate with Sealing film and mix the sample thoroughly
技术资料需要更多技术资料 索取更多技术资料