• 我要登录|
  • 免费注册
    |
  • 我的丁香通
    • 企业机构:
    • 成为企业机构
    • 个人用户:
    • 个人中心
  • 移动端
    移动端
丁香通 logo丁香实验_LOGO
搜实验

    大家都在搜

      大家都在搜

        0 人通过求购买到了急需的产品
        免费发布求购
        发布求购
        点赞
        收藏
        wx-share
        分享

        Standardization in Immunohistology

        互联网

        381
        The rapid acceptance of immunohistology as an invaluable adjunct to morphologic diagnosis has been possible because of the development of new and more sensitive antibodies and detection systems that allow its application to formalin-fixed, paraffin-embedded tissue (FFPT). More importantly, antigen-retrieval techniques have resulted in some degree of consistency allowing immunohistology to be used reliably as a diagnostic tool. The advent of prognostic and predictive biomarkers, and the desire for individualized therapy has resulted in mounting pressure to employ the immunohistological assay in a quantitative manner. While it was not a major issue when the technique was employed in a qualitative manner, the numerous variables in the preanalytical and analytical phases of the test procedure that influence the immunoexpression of proteins in FFPT become critical to standardization. Tissue fixation is pivotal to antigen preservation but exposure to fixative prior to accessioning by the laboratory is not controlled. Antigen retrieval, crucial in the analytical phase, continues to be employed in an empirical manner with the actual mechanism of action remaining elusive. There is great variation in reagents, methodology, and duration of tissue processing and immunostaining procedure, and the detection systems employed are not standardized between laboratories. While many of these variables are offset by the application of antigen retrieval, which enables the detection of a wide range of antigens in FFPT, the method itself is not standardized. This myriad of variables makes it inappropriate to provide meaningful comparisons of results obtained in different laboratories and even in the same laboratory, as in current practice, each specimen experiences different preanalytical variables. Furthermore, variables in interpretation exist and cutoff thresholds for positivity differ. Failure to recognize false-positive and false-negative stains leads to further errors of quantitative measurement. Many of the problems relating to the technology and interpretation of immunostaining originate from failure to recognize that this procedure is different from other histological stains and involves many more steps that cannot be monitored until the end result is attained. While several remedial measures can be suggested to address some of these problems, accurate and reproducible quantitative assessment of immunostains presently remains elusive as important variables that impact on antigen preservation in the paraffin-embedded biopsy �cannot be standardized.
        ad image
        提问
        扫一扫
        丁香实验小程序二维码
        实验小助手
        丁香实验公众号二维码
        扫码领资料
        反馈
        TOP
        打开小程序