        新鲜组织石蜡快速处理 Rapid Processing of Fresh Tissue into Paraffin

        互联网

        1332
         
        Rapid Processing of Fresh Tissue into Paraffin

        Fresh tissue < 2mm thick can be processed to a block ready to section in 2 hours. In the same period of time a needle biopsy will yield a stained cover-slipped slide for diagnosis.

        A. Formalin Fixation

        Fixative: 10% neutral buffered formalin
        Containers: Tissue placed in standard cassettes - the number of cassettes processed will determine fixative volume and container size.
        Water Loads: 500ml recirculated at the rear of the MW + 250ml on the left to create a cold spot.

         Protocol: Tissues < 2mm thick Tissue - Needle Biopsy
           TR: 40°C TR: 40°C
           40 min. at 450W 3 min. at 450W
          10 min. at 650W   (under vacuum- 20" Hg)

        B. Dehydration/Intermedium: These are straightforward steps that are done with a temperature restriction (TR). Rinse in fresh solution prior to each step. The dehydration and intermedium steps are described below.

        Reagent: Ethanol
        Containers: Tissue placed in standard cassettes - the number of cassettes processed will determine fixative volume and container size.
        Water Loads: 500ml recirculated at the rear of the MW + 250ml on the left to create a cold spot.

        Protocol: Ethanol Dehydration for tissues < 2mm in thickness - TR=40°C
        Rinse in 70% ethanol
        70% ethanol 5 min. at 450W
        95% ethanol 5 min. at 450W
        3 x 100% ethanol 5 min. each at 450W
        NOTE: For a needle biopsy the same steps are done except the time is reduced to 40 sec. for each step.
        Reagent:  Xylene
        Containers:  Tissue placed in standard cassettes - the number of cassettes processed will determine fixative volume and container size.
        Water Loads: 500ml recirculated at the rear of the MW +250ml on the left to create a cold spot.

        Protocol:  Inter medium for tissues < 2mm in thickness
          Fresh xylene for 5 min. at 450W and 5 min. at 550W (TR=45°C)
          Fresh xylene for 10min. at 650W (TR = 65°C)
        NOTE: For a needle biopsy, the same steps are done, except the time is reduced to 2.5 min. for each step

        C. Paraffin Step:
        Reagent: Paraplast® Plus
        Containers: Tissue placed in standard cassettes - the number of cassettes processed will determine fixative volume and container size.
        Water Loads: 500ml recirculated at the rear of the MW + 250ml on the left to create a cold spot.

        Protocol:  Paraffin infiltration for tissues < 2mm in thickness - TR = 63°C
          Rinse in warm (60°) paraffin
        Fresh paraffin for 10 min. at 650W - 2 vacuum cycleundefined
        Fresh paraffin for 10 min. at 650W - 2 vacuum cycleundefined
        Fresh paraffin for 10 min. at 650W - 2 vacuum cycleundefined
        ~undefinedcycle= 2 min. vacuum +2 min. no vacuum +2 min. vacuum +4 min. no vacuum
        (vacuum= 20" Hg; 500 torr)
        NOTE: For a needle biopsy, the same steps are done, except the time is reduced to 6 min. for each step. (the 4 min. no vacuum component of the 10 min. cycle is dropped)

        Conclusions:

        1. Microwave-assisted processing of tissues, from fixation through paraffin, can save time and produce better results, when the proper microwave technology is used to get the job done. The ability to control temperatures by a number of different parameters (variable wattage, temperature restrictive temperature probe and water recirculation) make it possible to achieve results that were not formerly available from other microwave processing systems or protocols. The technology makes it possible to employ any of the routinely used reagents for paraffin processing.

        2. Variable wattage eliminates the problems reported when tissues are transferred between solutions having different microwave transparencies.