产品封面图
文献支持

Human Nicotinamide Adenine Din

ucleotide Phosphate Oxidase 4 ELISA KIT
收藏
  • ¥2890
  • LSM Bio
  • 0.15-10ng/ml
  • 0.078ng/mL
  • 国产
  • ELA-E9433h
  • 2025年07月13日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 文献和实验
    • 技术资料
    • 灵敏度

      0.078ng/mL

    • 库存

      货源充足

    • 供应商

      LSM Bio

    • 检测范围

      0.15-10ng/ml

    • 检测方法

      夹心法/竞争法

    • 应用

      夹心法/竞争法ELISA体外定量检测小鼠血清、血浆或其它相关生物液体中蛋白浓度

    • 适应物种

    • 标记物

      Human Nicotinamide Adenine Dinucleotide Phosphate Oxidase 4

    • 样本

      血清、血浆或其它相关生物液体中天然和重组蛋白

    • 规格

      96T

    Human NOX4 ELISA Kit

    Packing.96Tests            Cat No. ELA-E9433h   

    INTENDED USE

    For the quantitative detection of Human Nicotinamide Adenine Dinucleotide Phosphate Oxidase 4 concentration in serum, plasma and other biological fluids.

     

    This package insert must be read in its entirety before using this product.

     

    If You Have Problems

    Our expert Technical Support Staff is available to assist you in answering your questions and resolving issues to ensure complete customer satisfaction.

     

    Please Contact Us

    Nova Lifetech Inc.
    Tel: (852)-81700345

    Website: www.lifescience-market.com

     

    In order to obtain higher efficiency service, please ready to supply the lot number of the kit to us (found on the outside of the box).

     

     

    REAGENTS AND MATERIALS PROVIDED

     

    Reagents

     

    Quantity

     

    Reagents

     

    Quantity

    Assay plate (96 Wells)

    1

    Instruction manual

    1

    Standard (lyophilized)

    2

    Sample Diluent

    1 x 20 mL

    Biotin-Conjugate (concentrate 100 x)

    1 x 120μL

    Biotin-Conjugate Diluent

    1 x 20 mL

    Streptavidin-HRP (concentrate 100 x)

    1 x 120μL

    Streptavidin-HRP Diluent

    1 x 20 mL

    Wash Buffer (concentrate 25 x)

    1 x 20 mL

    Substrate Solution

    1 x 12 mL

    Stop Solution

    1 x 10 mL

    Adhesive Films

    4


    MATERIALS REQUIRED BUT NOT SUPPLIED

           Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.

           Precision single or multi-channel pipettes and disposable tips.

           Deionized or distilled water.

           Eppendorf Tubes for serial dilution samples.

           Container for Wash Solution.

           Absorbent paper for blotting the microtiter plate.

     

     

    STORAGE

     

    Unopened kit

     

    Store at 2 - 8°C. Do not use past kit in expiration date.

     

     

     

     

     

     

    Opened/ Reconstituted Reagents

     

     

    Coated assay plate

     

    May be stored for up  to 1 month at 2 - 8°C. Return unused wells to the foil pouch containing the desiccant pack, reseal along entire edge of zip-seal, and avoid the damp.

    Standard

     

    May be stored for up  to 1 month at 2 - 8°C. If not for recent use, better keep it store at -20°C.

    Biotin-Conjugate

    Streptavidin-HRP

    Sample Diluent

     

     

     

    May be stored for up  to 1 month at 2 - 8°C.

    Biotin-Conjugate

    Diluent

    Streptavidin-HRP

    Diluent

    Wash Buffer

    Substrate Solution

    Stop Solution

     

    PRINCIPLE OF THE ASSAY

    This assay employs a two-site sandwich ELISA to quantitate NOX4 in Human serum, plasma. An antibody specific for NOX4 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any NOX4 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for NOX4 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of NOX4 bound in the initial step. The color development is stopped and the intensity of the color is measured.

    LIMITATIONS OF THE PROCEDURE

    FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.

    The kit should not be used beyond the expiration date on the kit label.

    Do not mix or substitute reagents with those from other lots or sources.

    It is important that the Calibrator Diluent selected for the standard curve be

    consistent with the samples being assayed.

           If samples generate values higher than the highest standard, dilute the samples with the appropriate Calibrator Diluent and repeat the assay.

           Any variation in standard diluent, operator, pipetting technique, washing

    technique, incubation time or temperature, and kit age can cause variation in binding.

           This assay is designed to eliminate interference by soluble receptors,

    binding proteins, and other factors present in biological samples. Until all factors have been tested in the ELISA Kit, the possibility of interference cannot be excluded.

    DETECTION RANGE

    31.25 pg/mL - 2000 pg/mL. The standard curve concentrations used for the ELISA’s were 2000 pg/mL, 1000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL,
    31.25 pg/mL, 0 pg/mL.

    SENSITIVITY

    The limit of detection of Human NOX4 defined as the analyte concentration resulting in an absorbance significantly higher than that of the dilution medium (mean plus 2 standard deviations) was determined to be 15.6 pg/mL (mean of 6 independent assays).

    SPECIFICITY

    This assay has high sensitivity and excellent specificity for detection of Human NOX4. No significant cross-reactivity or interference between Human NOX4 and analogues was observed.

    Note:

    Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between Human NOX4 and all the analogues, therefore, cross reaction may still exist.

    PRECISION

    Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in forty separate assays to assess inter-assay precision. CV (%) = SD/meanX100 Intra-Assay: CV<8%
    Inter-Assay: CV<12%

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    该产品被引用文献

    "Pioglitazone Enhances β-Arrestin2 Signaling and Ameliorates Insulin Resistance in Classical Insulin Target Tissues Authors: El-Fayoumi S. ·Mansour R. · Mahmoud A · Fahmy A. · Ibrahim I. Pharmacology  2021, Vol.106, No. 7-8 July 2021Pioglitazone Enhances β-Arrestin2 Signaling and Ameliorates Insulin Resistance in Classical Insulin Target Tissues Authors: El-Fayoumi S. ·Mansour R. · Mahmoud A · Fahmy A. · Ibrahim I. Pharmacology  2021, Vol.106, No. 7-8 July 2021"

    相关实验
    • A Microtiter-Plate Assay of Human NOS Isoforms

      Nitric oxide synthase (NOS) catalyzes the conversion of L -arginine, molecular oxygen, and nicotinamide adenine dinucleotide phosphate (NADPH) to NO, citrulline, and NADP+ (reviewed in ref. 1 ). The neuronal (n) and endothelial (e) NOS

    • Cloning and Expression of Human eNOS and nNOS Using the Baculovirus-Insect Cell System

      as a co-product and requires the presence of heme, tetrahydrobiopterin (BH4 ), nicotinamide adenine dinucleotide phosphate (NADPH), calmodulin (CaM), flavin mononucleotide (FMN), and flavine adenine nucleotide (FAD) (2 ). The NO generated by the family

    • Reactive Oxygen Release

      Monocytes, macrophages, neutrophils, and eosinophils are able to generate and release reactive oxygen species. The reactive oxygen species are generated by reduced nicotinamide adenine dinucleotide phosphate (NADPH) oxidase which is activated

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥1680
    上海康朗生物科技有限公司
    2025年07月09日询价
    询价
    南京赛戈巍生物科技有限公司
    2025年07月09日询价
    ¥960
    上海酶研生物科技有限公司
    2025年07月10日询价
    ¥960
    博辉生物科技(广州)有限公司
    2025年07月13日询价
    ¥1960
    科鹿(武汉)生物科技有限责任公司
    2025年09月03日询价
    文献支持
    Human Nicotinamide Adenine Dinucleotide Phosphate Oxidase 4 ELISA KIT
    ¥2890