    • 样本:

      液体

    • 标记物:

      HPV16L1

    • 适应物种:

      不限

    • 应用:

      科研单位

    • 检测方法:

      酶联免疫法

    • 检测范围:

      不限

    • 供应商:

      瓦兰生物

    • 库存:

      大量

    • 规格:

      96T

    人乳头瘤病毒16型L1(HPV16L1) ELISA试剂盒


    S
    ample
    collection and storages

    Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles
    Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Note: The samples should be centrifugated adequately and no hemolysis or granule was allowed.
    Materials required but not supplied
    1. Standard microplate reader(450nm)
    2. Precision pipettes and Disposable pipette tips.
    3. 37 ℃ incubator
    Precautions
    1. Do not substitute reagents from one kit to another. Standard, conjugate and microplates are matched for optimal performance. Use only the reagents supplied by manufacturer.
    2. Do not remove microplate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
    3. Mix all reagents before using.
    Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C)
    Materials supplied
    Name 96 determinations 48 determinations
    Microelisa stripplate 12*8strips 12*4strips
    Standard 0.3ml 0.3ml
    Sample diluent 6.0ml 3.0ml
    HRP-Conjugate reagent 10.0ml 5.0ml
    20X Wash solution 25ml 15ml
    Chromogen Solution A 6.0ml 3.0ml
    Chromogen Solution B 6.0ml 3.0ml
    Stop Solution 6.0ml 3.0ml
    Closure plate membrane 2 2
    User manual 1 1
    Sealed bags 1 1
    Note: Standard concentration was followed by:
    8、4、2、1、0.5、0 ng/ml.
    Reagent preparation
    20×wash solution:Dilute with Distilled or deionized water 1:20.
    Assay procedure
    1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.
    2. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.
    3. Add Sample: Add testing sample 10μl Then add sample diluent 40μl to testing sample well; Blank well doesn’t add anyting.
    4. Add 100μl of HRP-conjugate reagent to each well, cover with an adhesive strip and incubate for 60 minutes at 37°C.
    5. Aspirate each well and wash, repeating the process four times for a total of five washes. Wash by filling each well with Wash Solution (400μl) using a squirt bottle, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    6. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.
    7. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not


    appear uniform, gently tap the plate to ensure thorough mixing.
    8. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.
    Calculation of results
    1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
    2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
    3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
    4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
    5. The sensitivity by this assay is 0.1 ng/ml.
    6. Standard curve


    Storage: 2-8℃.
    validity: six months.

    FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!


    试剂盒组成
    名称 96孔配置 48孔配置 备注
    微孔酶标板 12孔×8条 12孔×4条 无
    标准品 0.3mL 0.3mL 无
    样本稀释液 6mL 3mL 无
    检测抗体-HRP 10mL 5mL 无
    20×洗涤缓冲液 25mL 15mL 按说明书进行稀释
    底物A 6mL 3mL 无
    底物B 6mL 3mL 无
    终止液 6mL 3mL 无
    封板膜 2张 2张 无
    说明书 1份 1份 无
    自封袋 1个 1个 无
    注:标准品浓度依次为:20、10、5、2.5、1.25、0 ng/mL.
    试剂的准备
    20×洗涤缓冲液的稀释:蒸馏水按1:20稀释,即1份的20×洗涤缓冲液加19份的蒸馏水。
    洗板方法
    1. 手工洗板:甩尽孔内液体,每孔加满洗涤液,静置1min后甩尽孔内液体,在吸水纸上拍干,如此洗板5次。
    2. 自动洗板机:每孔注入洗液350μL,浸泡1min,洗板5次。
    操作步骤
    1. 从室温平衡60min后的铝箔袋中取出所需板条,剩余板条用自封袋密封放回4℃。
    2. 设置标准品孔和样本孔,标准品孔各加不同浓度的标准品50μL;
    3. 待测样本孔先加待测样本10μL,再加样本稀释液40μL;
    4. 随后标准品孔和样本孔中每孔加入辣根过氧化物酶(HRP)标记的检测抗体100μL,用封板膜封住反应孔,37℃水浴锅或恒温箱温育60min。
    5. 弃去液体,吸水纸上拍干,每孔加满洗涤液,静置1min,甩去洗涤液,吸水纸上拍干,如此重复洗板5次(也可用洗板机洗板)。
    6. 每孔加入底物A、B各50μL,37℃避光孵育15min。
    7. 每孔加入终止液50μL,15min内,在450nm波长处测定各孔的OD值。
    结果判断
    绘制标准曲线:在Excel工作表中,以标准品浓度作横坐标,对应OD值作纵坐标,绘制出标准品线性回归曲线,按曲线方程计算各样本浓度值。

    试剂盒性能
    1. 准确性:标准品线性回归与预期浓度相关系数R值,大于等于0.9900。
    2. 灵敏度:最低检测浓度小于0.1 ng/mL。
    3. 特异性:不与其它可溶性结构类似物交叉反应。
    4. 重复性:板内变异系数小于10%、板间变异系数小于15%。
    5. 贮藏:2-8℃,避光防潮保存。
    6. 有效期:6个月
    免责声明
    1. 试剂盒仅供研究使用,不得用于临床实验或人体实验,否则所产生的一切后果,由实验者承担,本公司概不负责。
    2. 严格按照说明书操作,实验者违反说明书操作,后果由实验者承担。

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标询价记录
    图标暂无询价记录
    图标文献和实验
    相关实验
    • 一文了解 PD-L1 最新进展

      药(Opdibo)和 K 药(Keyduda)相继于今年 6 月和 7 月份在国内获批上市,也给国内非小细胞肺癌和恶性转移黑色素瘤患者带来了福音。PD-L1 在患者体内的表达会严重影响 PD1/PD-L1 单抗药物的治疗效果,目前已有获批的 PD-L1 组织病理伴随诊断试剂盒,用于临床分组和预后分析。肿瘤微环境设计要素众多,关系复杂。伴随诊断类 PD-L1 临床诊断试剂盒,受限于单一标记和单一表达量检测,无法准确揭示复杂免疫微环境与免疫治疗的深度关系,从而影响治疗效果及预后分析。接下

    • L1和L8是什么类型的柱子?它是怎么规定的?

            L1和L8是美国药典(USP)规定的色谱柱编号,其实就是ODS柱和NH2柱。下面是USP规定的编号所对应的色谱柱类型。 L1:十八烷基键合多孔硅胶或无机氧化物微粒固定相,简称ODS柱 L2:30~50mm表面多孔薄壳型键合十八烷基固定相,简称C18柱 L3:多孔硅胶微粒,即一般的硅胶柱 L4:30~50mm表面多孔薄壳型硅胶柱 L5:30~50mm表面多孔薄壳型氧化铝柱 L6:30~50mm实心微球表面包覆磺化碳氟聚合物,强阳

    • 脂滴诱导出不来?3T3-L1细胞成脂分化完整实验方案收好!

      ,根据总蛋白浓度得到脂质积累水平。 5.功能学评估(进一步) ·胰岛素刺激葡萄糖摄取实验(胰岛素敏感性) ·β受体激动剂诱导脂解,检测释放游离脂肪酸FFA、甘油 ·ELISA检测上清脂联素、瘦素、炎症因子 六、分化失败常见原因 尽管前文已经明确了操作流程与结果评估,但在实际培养中,3T3-L1的诱导分化往往并非一帆风顺。当面临脂滴“千呼万唤不出来”的窘境时,不妨先来看看以下几个常见问题,进行排查: 1、传代过多,需换新批次细胞 2、没有选择高质量的血清 3、汇合后未静置48h,细胞仍增殖 4、MDI中

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥1600
    瑟瑞娜生命科学技术发展(上海)有限公司
    2026年07月23日询价
    ¥1200
    蒂科(上海)生物科技有限公司
    2026年05月29日询价
    ¥500
    武汉纯度生物科技有限公司
    2025年07月12日询价
    询价
    上海维亦特生物科技有限公司
    2025年07月15日询价
    ¥880
    上海富雨生物科技有限公司
    2026年07月17日询价
    人乳头瘤病毒16型L1(HPV16L1) ELISA试剂盒