BIO-RAD
- 规格:
MSB1001
Choose Microseal 'B' Adhesive Sealing Films for all thermal cycling, including real-time PCR and next generation sequencing (NGS) applications. These peelable seals can be used for storage and transport of plates. Perforated end tabs can be removed when using this sealer with automated plate handlers.
- Clear polyester for high sensitivity optical assays
- Suitable for all PCR plates and automated plate handlers
- Low volume PCR — down to 5 μl in 384-well plates, or 10 μl in 96-well plates
- Adhesive effective down to –40°C
- Free of DNase, RNase, and human DNA
Product Options
A range of films, seals, and foils are available. Choose the best options for your protocols.
| Films & Foils |
Sealing |
Optical (qPCR) |
Storage, Min Temp |
Features/Uses |
Catalog Number |
| Microseal 'A' Film |
Pressure |
— |
— |
Peelable, low volume PCR. Ideal for sample transport |
|
| Microseal 'B' Film |
Adhesive |
+ |
–40°C |
Peelable, low volume PCR, automated plate handler compatible. Ideal for NGS workflows and qPCR |
MSB1001 |
| Microseal 'C' Film |
Pressure |
+ |
–70°C |
Peelable, raised well rim compatible |
|
| Microseal 'F' Foil |
Adhesive |
— |
–70°C |
Pierceable, automated system compatible. High DMSO resistance |
|
| Optically Clear Heat Seal§ |
Heat Sealer |
+ |
–80°C |
Peelable, validated for qPCR |
|
| Permanent Clear Heat Seal§ |
Heat Sealer |
— |
–80°C |
Permanent, water bath cycling, high DMSO resistance |
|
| Pierceable Foil Heat Seal§ |
Heat Sealer |
— |
–20°C |
Pierceable, validated for Droplet Digital PCR, high DMSO resistance |
|
| Peelable Foil Heat Seal§ |
Heat Sealer |
— |
–200°C |
Peelable, liquid nitrogen storage compatible |
§Validated with the PX1 PCR Plate Sealer
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
- 作者
- 内容
- 询问日期
文献和实验E-Z 96® Viral RNA Protocol with Centrifugation
into the each well of the HiBind® RNA plate . Seal the plate with a new sealing film. Centrifuge at 5500 x g for 5 minutes at room temperature. 11. Place HiBind® RNA plate on top of another clean 2ml 96-well plate (Not supplied). Remove the sealing film and add 500 ul Wash
. Much worse variants: "Adhesive Sealing Sheet" from ABgene : (hardly removable, expensive); Microseal "A" film. Fragile: don't press the PCR machine cover very tightly, it can damage Microseal
and unsuitable for freezing. For Microseal "A" film: when PCR is finished - immediately (plate still in the PCR block) take off the upper film; take the plates out of PCR machine;
技术资料暂无技术资料 索取技术资料