Human CXCL9 / MIG ELISA Kit (CLIA) - LS-F26284
Performance 100% Guaranteed
Print This Page
Technical Help
Review This Product
SpecificationsPublicationsReviewsImages
Mouse CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F275
Reactivity: Mouse
Range: 2.74-2000 pg/ml
Mouse CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F7477
Reactivity: Mouse
Range: 15.63-1000 pg/ml
Human CXCL9 / MIG ELISA Development Kit - LS-F31391
Reactivity: Human
Range: 16-1000 pg/ml
Human CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F153
Reactivity: Human
Range: 8.23-2000 pg/ml
Human CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F590
Reactivity: Human
Range: 16-1000 pg/ml
More CXCL9 / MIG Products
Top of Page
CLIA (chemiluminescent immunoassay) kit
Target
CXCL9 / MIG
Synonyms
CXCL9, Crg-10, Humig, SCYB9, Small-inducible cytokine B9, C-X-C motif chemokine 9, CMK, MIG
Reactivity
Human
Specificity
Monokine Induced By Interferon Gamma (MIg)
Manual
Intended Sample Types
Plasma, Serum
Format
96-Well Strip Plate
Detection
Chemiluminescent
Measurement
Quantitative
Detection Range
13.72 - 10000 pg/ml
Sensitivity
5.6 pg/ml
Assay Time
4.5 h
Precision
Intra-Assay: CV<10% Inter-Assay: CV<12%
Storage
Short term: 4°C; Long term: see manual.
Quality Assurance
Due to their limited shelf life, LSBio ELISA kits are not typically stocked as finished goods. Upon receipt of an order each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Range, Sensitivity, and Precision. In the event of a significant change the order would be confirmed with the customer before shipping ELISA kit lot numbers reflect the date of final assembly and testing for each specific kit rather than a bulk manufactured lot. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
Kit Components
Restrictions
For research use only.
Guarantee
This elisa kit carries the LSBio 100% Guarantee.
About CXCL9 / MIG
Cytokine that affects the growth, movement, or activation state of cells that participate in immune and inflammatory response. Chemotactic for activated T-cells. Binds to CXCR3. Q07325 NM_002416NP_002407.1
Top of Page
Submit a Publication
Top of Page
Submit a Review
Top of Page
Sandwich CLIA Platform Overview
Performance 100% Guaranteed
Print This Page
Technical Help
Review This Product
SpecificationsPublicationsReviewsImages
Popular CXCL9 / MIG Elisa Kits
Mouse CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F275
Reactivity: Mouse
Range: 2.74-2000 pg/ml
Mouse CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F7477
Reactivity: Mouse
Range: 15.63-1000 pg/ml
Human CXCL9 / MIG ELISA Development Kit - LS-F31391
Reactivity: Human
Range: 16-1000 pg/ml
Human CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F153
Reactivity: Human
Range: 8.23-2000 pg/ml
Human CXCL9 / MIG ELISA Kit (Sandwich ELISA) - LS-F590
Reactivity: Human
Range: 16-1000 pg/ml
Product Description
LS-F26284 is a 96-well enzyme-linked immunosorbent assay (ELISA) for the Quantitative detection of Human CXCL9 / MIG in samples of Plasma and Serum. It is based upon a Sandwich CLIA assay principle and can be used to detect levels of CXCL9 / MIG as low as 5.6 picograms per milliliter.More CXCL9 / MIG Products
Top of Page
Specifications
TypeCLIA (chemiluminescent immunoassay) kit
Target
CXCL9 / MIG
Synonyms
CXCL9, Crg-10, Humig, SCYB9, Small-inducible cytokine B9, C-X-C motif chemokine 9, CMK, MIG
Reactivity
Human
Specificity
Monokine Induced By Interferon Gamma (MIg)
Manual
Intended Sample Types
Plasma, Serum
Format
96-Well Strip Plate
Detection
Chemiluminescent
Measurement
Quantitative
Detection Range
13.72 - 10000 pg/ml
Sensitivity
5.6 pg/ml
Assay Time
4.5 h
Precision
Intra-Assay: CV<10% Inter-Assay: CV<12%
Storage
Short term: 4°C; Long term: see manual.
Quality Assurance
Due to their limited shelf life, LSBio ELISA kits are not typically stocked as finished goods. Upon receipt of an order each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Range, Sensitivity, and Precision. In the event of a significant change the order would be confirmed with the customer before shipping ELISA kit lot numbers reflect the date of final assembly and testing for each specific kit rather than a bulk manufactured lot. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
Kit Components
- Adhesive Plate Sealers
- Coated 96-well Strip Plate
- Standard (Lyophilized)
- Sample Diluent
- Assay Diluent A
- Assay Diluent B
- Detection Reagent A (Green)
- Detection Reagent B (Red)
- Wash Buffer (30x)
- Substrate A
- Substrate B
Restrictions
For research use only.
Guarantee
This elisa kit carries the LSBio 100% Guarantee.
About CXCL9 / MIG
Cytokine that affects the growth, movement, or activation state of cells that participate in immune and inflammatory response. Chemotactic for activated T-cells. Binds to CXCR3. Q07325 NM_002416NP_002407.1
Top of Page
Publications (0)
Submit a Publication
Top of Page
Customer Reviews (0)
Submit a Review
Top of Page
Images
Sandwich CLIA Platform Overview
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验相关实验
High‐Throughput, Multiplexed Analysis of 3‐Nitrotyrosine in Individual Proteins
Figure 17.15.4 Defining a useful dilution of human plasma for measuring 3‐nitrotyrosine. ELISA microarray results for the dilution of human plasma. Four samples were diluted with 0.1% BSA/PBS at 2‐, 5‐, 10
技术资料暂无技术资料 索取技术资料
Human CXCL9 / MIG ELISA Kit (CLIA) - LS-F26284
$990