产品封面图

自由氯-DPD检测试剂盒

收藏
  • ¥1200
  • WAKO
  • 297-56501
  • 2025年08月13日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 文献和实验
    • 技术资料
    • 保存条件

      室温

    • 英文名

      Active Cl-DPD Test wako

    • 供应商

      北京拜尔迪生物技术有限公司

    • 规格

      100 tests

    等级:for Residual Chlorine Analysis This is a simple measurement kit using tablets, but it can still obtain measured data similar to the Test Methods for Drinking Water. Kit Contents: DPD Tablet (Mixture tablet of 0.002 g of DPD and 0.048 g of Sodium Sulfate, Anhydrous) ... 1 bottle x 100 tables KI Tablet (0.05 g of Potassium Iodide/tablet) ... 1 bottle x 100 tablet Phosphate Buffer Solution (pH 6.5) ... 1 bottle x 8 mL Color Tone Table ... 1 sheet Features: Easy operation (1) No weighing is required for DPD (N, N-Diethyl-p-phenylenediamine Sulfate), KI (potassium iodide) because they are supplied in tablets.(2) For the buffer solution, the concentrated liquid is supplied in a convenient dropper bottle.(3) Measurement can be made by comparing the developed color with the color tone table. Measurements are possible with one test tube. (1) Both free residual chlorine and combined residual chlorine can be measured in one test tube. Chlorine is used for sterilization and disinfection of drinking water and swimming pool water. Chlorine displays disinfecting action in the form of hydrochlorous acid in water, but reacts with suspended matters, organic matters, metallic salts, etc. in water or dissipates in the atmosphere, and its concentration lowers and disinfecting action is lost. Therefore, residual chlorine in water is measured from the viewpoint of health management.Presently, the orthotolidine method is a mainstream of residual chlorine measurement, but carcinogenicity of orthotolidine has been pointed out and the DPD method has been attracting attention of the people concerned.The DPD method measures residual chlorine by comparing the standard colorimetric liquid to pink to pinkish red color developed by allowing residual chlorine to react with diethyl-p-phenylenediamine (DPD).The present product is a simplified residual chlorine analysis kit with this DPD method adopted as the working principle.

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • 不同生化分析仪检测血浆和血清总胆红素的比较

            胆红素是体内衰老的红细胞经网状内皮系统的破坏和肝脏转化的代谢产物,其含量的变化对疾病的诊断具有重要意义。总胆红素的检测方法常用的有重氮试剂法、胆红素氧化酶法以及直接分光光度计法。作者采用二苯重氮盐法(DPD法)的两种试剂盒以及Roche Modular P和Bayer RA-1000型生化分析仪,检测血清和血浆总胆红素(TBil),结果报告如下。      1    材料与方法         1.1    标本

    • 从毒品到抗抑郁药物,中国研究团队 Nature 揭示「K 粉

      胺酮在受体结合口袋内的动态构象改变,发现胺酮在空腔内存在「upper(向上)」和「lower(向下)」两种构象,而冷冻电镜捕捉到了「upper」构象。通过结合自由能分析发现 GluN2A-L642 对胺酮结合发挥着至关重要的作用,其疏水侧链可与胺酮形成疏水作用,同时发现 GluN1-N616 会与胺酮形成氢键作用。接着,研究者们进行了 TEVC 电生理实验证实胺酮抑制了 GluN1-GluN2A 受体,并通过一系列蛋白点突变实验,证实了分子动力学模拟的结论,GluN1-N616

    • ROS的检测方法

      resonance(EPR,电子顺磁共振谱)Detection of ROS(活性氧类物质/活性氧)by election paramagnetic resonance(EPR,电子顺磁共振谱)(胰腺组织的ROS生成)。(2) ; ;DCF法: dichlorofluorescein (DCF)二荧光黄[1,8,13]活性氧检测试剂盒是利用荧光探针DCFH-DA进行活性氧检测的。DCFH-DA本身没有荧光,可以自由穿过细胞膜,进入细胞内后,可以被细胞内的酯酶水解生成DCFH。而DCFH不能通透细胞膜,从而使

    图标技术资料

    暂无技术资料 索取技术资料

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥150
    上海泽叶生物科技有限公司
    2025年06月21日询价
    ¥1
    上海钰博生物科技有限公司
    2025年06月21日询价
    ¥1
    上海康朗生物科技有限公司
    2025年06月21日询价
    ¥99
    上海圻明生物科技有限公司
    2025年07月12日询价
    ¥1540
    北京拜尔迪生物医药技术有限公司
    2025年08月13日询价
    自由氯-DPD检测试剂盒
    ¥1200