相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 规格:
1.0 ml
来源:Rabbit
参考文献:1. Ong G.L. and Mattes M.J. Mouse strains with typical mammalian levels of complement activity. J Immunol Methods 125:147-158, 1989. 2. van Dijk, H. et al. Estimation of classical pathway of mouse complement activity by use of sensitized rabbit erythrocytes. J Immunol Methods 39:257-268, 1980. 3. Terry W.D. et al. Differences in serum complement activity among inbred strains of mice. J Immunol. 92:576-578, 1964. 4. Nilsson U.R. and Muller-Eberhard, H.J. Deficiency of the fifth component in mice with an inherited complement defect. J Exp. Med. 124:1-16, 1967. 5. Wetsel, R.A. et al. Deficiency of the murine fifth complement component (C5). A 2-base pair gene deletion in a 5’-exon. J. Biol. Chem. 265:2435-2440, 1990.
官网链接:http://www.complementtech.com/product-description/MCAR%20.htm
商品关键词:MCAR (Mouse Complement Assay Reagent),B250,CompTech
简单描述:Mouse complement is famously difficult to assay. Mouse serum rapidly loses its activity and the typical titer of mouse serum is far below the 150-200 CH50 units/mL found with human serum. Mouse strains differ greatly in their complement CH50 titers (Ref 1, 2 & 3) and a great many common mouse strains are genetically deficient in C5 (Ref 4 & 5) meaning that they cannot lyse cells even if they have an otherwise fully functional complement system. The exact reasons for low titers in C5 sufficient strains are not entirely clear and they may be different for different mouse strains. However, a common reason is that mouse classical pathway components are not efficiently activated by the standard antibodies bound to EA. At Complement Technology, Inc. we have developed a unique hemolytic reagent (MCAR = Mouse Complement Assay Reagent) that sensitizes sheep erythrocytes to provide improved mouse CH50 titers. For example, commercially available mouse complement exhibited a CH50 of only ~12 units/mL in the assay system described below, however, with MCAR present the CH50 was 217. That is 18-fold higher complement titer with MCAR. This is numerically comparable to normal human serum CH50, but the assays are different. At this time we cannot say how many mouse strains this reagent will work with, but we have used MCAR with three and it worked equally well with all. Mouse serum is also extremely unstable outside of the mouse. We have observed a rapid loss of activity after thawing (100% loss if left at 4oC overnight). Thus, we advise rapidly thawing NMS and immediately using it in assays or if it is necessary aliquoting and freezing the NMS. It should be thawed rapidly in a water bath, moved immediately to wet ice when thawed, aliquoted and re-frozen as rapidly as possible. Upon use, thaw only when the experimental setup is ready for the NMS sample and keep it on wet ice after thawing.
Concentration: > 0.4 mg/mL
Form: Frozen solution
Preservative: 0.025% sodium azide
Assays: In complement assays every lot of mouse complement will be have a different titer even from the same strain of mice. Preliminary assays will need to be done to determine the correct amount of NMS to use. Normal sensitized sheep cells (EA) work well if the lysis is boosted by MCAR. Most NMS samples generally contain a lot of hemoglobin and therefore the more serum used the higher the background. A sample assay protocol is shown in the table below where the total assay volume was kept to a minimum at 100 uL/assay. In general, tubes should be set up with buffers and MCAR at room temperature. Then EA are added, mixed and incubated 5 min at room temperature. After MCAR has incubated with the EA cells for 5 min or more at room temp the NMS is added to start the assay. The tubes should be mixed and moved to a 37oC water bath for 30 min with occasional (every 5-10 min) resuspension by vortexing. One word of caution, do not centrifuge the EA after they have been mixed with MCAR and do not make a master mix of EA and MCAR and then pipette into the tubes. These procedures will result in inconsistent results. % Lysis is calculated by subtracting the background A415 values (average of #1 and 2) from the A415 values for each of the experimental assays (e.g. #7-22) and dividing by the maximum lysis (average of #5 and 6) minus background and then multiplying by 100.After 30 min at 37oC, the assays are diluted with 200 uL cold GVBE, mixed by vortexing, centrifuged to pellet the unlysed cells and 200 uL of the supernatant should be transferred to a flat-bottomed microplate and the absorbance read at 415 nm. Alternatively a microcuvette and spectrophotometer may be used. EA are used at 5 x 108/ml in GVB++ and all dilutions are done in GVB++ buffer.
官网链接: www.annoron.com
办公电话: 010-56256916
官方售后: 400-965-8633
企业QQ: 3198592576、3212874516
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验本制品是一种快速方便的总RNA提取试剂,可以从动物组织、植物材料、各种微生物、培养细胞等中提取总RNA。样品在RNAiso Reagent中能够充分被裂解,在加入氯仿离心后,溶液会形成上清层、中间层和有机层(下层),RNA分布在上清层中,收集上清层后,经异丙醇沉淀便可以回收得到总RNA。RNAiso Reagent具有很强的广谱性,可以适用于各种样品的总RNA提取,提取过程方便快速,整个操作在一小时内便可以完成。经本制品提取的总RNA纯度高,基本不含蛋白质及基因组 DNA,提取的RNA可以直接
The Sophisticated Mouse: Protecting a Precious Reagent
Definable, genetically and environmentally, the humble mouse has become a reagent with which to probe the human condition. The information thus gained is leading to a greater understanding of inter-individual variation in drug responses
Purification and Characterization of Human and Mouse Complement C3
by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and hemolysis assays. The hemolysis assay is a standard technique to assess complement activity monitoring the lysis of red blood cells.
技术资料暂无技术资料 索取技术资料