相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 样本:
血清、血浆、尿液、组织、上清液
- 库存:
60
- 标记物:
详见官方网站
- 适应物种:
Human
- 应用:
ELISA
- 检测方法:
酶联免疫方法
- 检测范围:
详见说明书
- 供应商:
钰博生物
- 规格:
96 tests
| For quantitative detection in human samples. | (no photo available) | 96 tests | $975 | KT-61729 |
| Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 |
| Calibrator | 2 |
| Calibrator Diluent | 1 × 20 mL |
| Detection Reagent A | 1 × 120 uL |
| Detection Reagent B | 1 × 120 uL |
| Assay Diluent A | 1 × 12 mL |
| Assay Diluent B | 1 × 12 mL |
| TMB Substrate | 1 × 9 mL |
| Stop Solution | 1 × 6 mL |
| Wash Buffer (30X concentrate) | 1 × 20 mL |
| Plate sealer for 96 wells | 4 |
- Microplate reader with 450 ± 10 nm filter.
- Precision single or multi-channel pipettes and disposable tips.
- Eppendorf Tubes for diluting samples.
- De-ionized or distilled water.
- Absorbent paper for blotting the microtiter plate.
- Container for Wash Solution. STORAGE All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon being received while the others should be at 4°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable for 1 month, provided it is stored as prescribed above.
Plasma
Collect plasma using 3.8% sodium citrate (sodium citrate:blood = 1:9) as an anticoagulant. Centrifuge samples for 15 minutes at 1000 × g at 4°C within 30 minutes of collection. Remove plasma and assay immediately or store
samples in aliquot at -20°C or -80°C for later use. Avoid repeated freeze/thaw cycles. Note:
- Samples to be used within 5 days may be stored at 4°C, otherwise samples must be stored at -20°C (≤1 month) or -80°C (≤2 months) to avoid loss of bioactivity and contamination.
- When performing the assay slowly bring samples to room temperature. 3. Sample hemolysis will influence the result, so hemolytic specimen can not be detected.
Bring all kit components and samples to room temperature (18-25°C) before use.
Detection Reagent A and B
Briefly spin or centrifuge the stock Detection Reagent A and Detection Reagent B before use. Dilute to the working concentration with Assay Diluent A or B, respectively (1:100).
Wash Solution
Dilute 20 mL of Wash Solution concentrate (30X) with 580 mL of de-ionized or distilled water to prepare 600 mL of Wash Solution (1X).
ASSAY PROCEDURE SUMMARY
- Prepare all reagents, samples and calibrators;
- Add 100 µL calibrator or sample to each well. Incubate 2 hours at 37°C;
- Add 100 µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
- Aspirate and wash 3 times;
- Add 100 µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
- Aspirate and wash 5 times;
- Add 90 µL Substrate Solution. Incubate 15-25 minutes at 37°C;
- Add 50 µL Stop Solution. Read at 450 nm immediately.
1. The final experimental results will be closely related to operation skills of the end users and theexperimental environments. Please make sure that sufficient samples are available.
2. Kits from different batches may be a little different in detection range, sensitivity and color developingtime. Please perform the experiment exactly according to the instruction attached in kit whileelectronic ones from our website (www.k-assay.com) is only for information.
3. Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied bymanufacturer.
4. Protect all reagents from strong light during storage and incubation. All the bottle caps of reagentsshould be covered tightly to prevent the evaporation and contamination of microorganism.
5. There may be some foggy substance in the wells when the plate is opened at the first time. It will nothave any effect on the final assay results. Do not remove microtiter plate from the storage bag untilneeded.
6. Wrong operations during the reagents preparation and loading, as well as incorrect parameter settingfor the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10 nmor less and an optical density range of 0-3 O.D. or greater at 450 ± 10 nm wavelength is acceptablefor use in absorbance measurement. Please read the instruction carefully and adjust the instrumentprior to the experiment.
7. Even the same operator might get different results in two separate experiments. In order to get betterreproducible results, the operation of every step in the assay should be controlled. Furthermore, apreliminary experiment before assay for each batch is recommended.
8. Each kit has been strictly passed Q.C. test. However, results from end users might be inconsistentwith our in-house data due to some unexpected transportation conditions or different lab equipments.
Intra-assay variance among kits from different batches might arise from above factors, too.
9. Kits from different manufacturers for the same item might produce different results, since we haven’tcompared our products with other manufacturers.
10. The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, andclothing protection when using this material.
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验ABI SOLiD sequencing is a form of DNA sequencing. DNA sequencing encompasses biochemical methods for determining the order of the nucleotide bases, adenine, guanine, cytosine, 5-methyl cytosine, and thymine, in a DNA oligonucleotide
10.21 华中科技大学 Nature 子刊揭示精母细胞中逆转录转座子沉默的分子机制
nucleotide translocator, ANT)的基因中的突变会导致很多疾病,比如心脏病和眼肌无力,但是这些突变如何引发疾病的内在机制尚不清楚。如今,在一项新的研究中,来自美国宾夕法尼亚大学佩雷尔曼医学院的研究人员揭示了 ANT 的令人惊讶的新功能:ANT 对于一种称为线粒体自噬(mitophagy)---通过清除受损的线粒体,有助于确保线粒体网络的完整性---的质量控制过程至关重要,并且发现导致这种质量控制系统出现缺陷的 ANT 突变最终会导致心脏病。该研究有助于研究如何抵消对线粒体自噬的抑制
缩写 全称 中文 AA autoantibody 自身抗体 AAF aminoacetylfluorescence 氨乙酰基荧光 Ab antibody 抗体 ABC avidin-biotin peroxidase complex 抗生物素(亲合素)-生物素-过氧化物酶复合物 ACh acetycholine 乙酰胆碱 AChR acetycholine receptor 乙酰胆碱受体 AChRAb acetycholine
技术资料暂无技术资料 索取技术资料










