产品封面图

NxSeq® AmpFREE Low DNA Library

Kit
收藏
  • ¥12184.83
  • Lucigen已认证
  • http://www.lucigen.com/docs/manuals/MA163-NxSeq-AmpFREE-Low-DNA-Library-Kit.pdf
  • 2025年11月15日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 文献和实验
    • 技术资料
    • 保存条件

      -20º C

    • 英文名

      NxSeq® AmpFREE Low DNA Library Kit

    • 库存

      大量

    • 供应商

      中北林格

    • 规格

      48 rxn

    NxSeq® AmpFREE Low DNA

    Library Kits and Adaptors (Illumina-compatible)

    产品说明书

    The highest efficiency, low input, pcr-free fragment library prep kit available at the lowest cost.

    • Low Input: Requires as little as 75 ng of sheared input DNA allowing use of limiting samples.
    • High Efficiency: Optimized adaptor ligationproduces more sequenceable fragments in each library, yielding better coverage & depth from single or multiplexed libraries.
    • PCR-free: Prevents the introduction of PCR-bias, providing more uniform coverage.
    • Fast: 2 hour, 10 minute protocol saves you time and gets your samples on the sequencer sooner.
    • Affordable: Best priced and best performing kit available.

    You’re doing next gen sequencing for a reason; you want big data! To get there, you know you need the best fragment libraries possible to get the most information out of each sample. So why spend your time, resources and expensive sequencing reagents on anything but the best fragment DNA libraries?

    The NxSeq® AmpFREE Low DNA Library Kit allows you to build the best fragment DNA libraries possible. We optimized each step of the protocol to ensure peak performance on Illumina sequencers. In addition, these kits require only 75 ng of sheared DNA input, and produce libraries in about 2 hours using a streamlined, easy to follow protocol.

    • Better Data
      • Higher Efficienency Libraries
      • More Reads from Challenging FFPE Samples
      • Excellent Sequencing Data Examples
      • Minimal GC Bias
    • Lower Price
    • Faster, Easier Protocol

    Higher Efficiency Libraries

    More Sequenceable DNA Fragments per Library = More Data

    NxSeq Fragment Library Kit Most Efficient

    Figure 1. Percentage of library DNA with correctly ligated adaptors measured by qPCR. Duplicate libraries were prepped per kit/organism (Human, Staphylococcus aureus, Rhodobacter sphaeroides (1 library only), and E. coli) according to the manufacturer’s recommended input amounts and protocols. Adaptor ligation efficiency was measured by qPCR using the KAPA Library Quantification Kit (Complete ROX Low, cat #KK4873) and matching amplified library as an internal standard.


    More Reads from Challenging FFPE Samples

    Better Libraries Increase the Number of Reads per Library

    Library Kit DNA Input Total Number of Sequencing Reads Per Library
    Staphylococcus aureus E. coli K12
    NxSeq® AmpFREE Low DNA Library Kit 75 ng 5,649,946 4,305,882
    Kapa Hyper Prep Kit 250 ng 4,838,726 (-15%) 1,647,452 (-62%)
    Illumina TruSeq DNA PCR-Free Library Prep Kit 1 µg 38,768 (-99%) 1,543,558 (-64%)

    Figure 2a. Number of sequencing reads generated per library after multiplexing and running on a MiSeq Instrument. DNA fragment libraries were prepped in parallel for each kit/organism according to the manufacturer’s recommended input amounts and protocols. Libraries were quantitated and normalized to 2 nM using the Bioanalyzer (size) and Qubit Fluorometer (amount). Equimolar amounts of each library were multiplexed and sequenced with a single MiSeq run using 2 ×150 bp chemistry. The number of sequencing reads obtained are shown as well as the percent reduction (%) in total reads compared to the appropriate NxSeq AmpFREE Kit results.

    More Proof with Challenging FFPE Samples

    Library Kit Sample Type Input Amount Total Reads Mapped Reads
    (repeat masked)
    NxSeq® AmpFREE Low DNA Library Kit Normal gDNA 75 ng 2,163,636 900,338
    FFPE DNA 75 ng 1,767,818 688,074
    FFPE DNA 150 ng 1,706,714 656,658
    Kapa Hyper Prep Kit Normal gDNA 250 ng 1,567,276 (-28%) 650,296 (-28%)
    FFPE DNA 250 ng 1,270,870 (-28%) 487,872 (-29%)

    Figure 2b. Number of sequencing reads generated from matching normal and FFPE gDNA sample libraries. DNA fragment libraries were prepped using the two indicated kits according to the manufacturer’s recommended input amounts and protocols. Libraries were constructed from normal gDNA (Biochain, Cat. No. D1234142-S02) and DNA extracted from a matching FFPE human kidney tissue (Biochain Cat. No. T2234142-S02) using the Qiagen AllPrep DNA/RNA FFPE Kit. The gDNA samples were sheared to ~250 bp before starting library construction. Final libraries were quantitated and normalized to 2 nM using the Bioanalyzer (size) and Qubit Fluorometer (amount). Equimolar amounts of each library were multiplexed and sequenced with a single MiSeq run using 2 × 150 bp chemistry. The number of sequencing reads obtained are shown as well as the percent reduction (%) in total and mapped reads compared to the corresponding NxSeq AmpFREE Kit results using 75 ng of input DNA.


    Highly Mappable Reads (>92%) from Human, Staphylococcus andRhodobacter gDNA Sequencing

    Sequencing Stat

    Human Staphylococcus

    Rhodobacter

    Genome size, GC percentage

    ~3 Gbp 45% GC

    2,821,361 33% GC

    4,602,977 69% GC

    Raw reads

    3,131,114

    1,260,836

    3,900,174

    Mapped reads

    2,979,237 (95.15%)

    1,174,111 (93.12%)

    3,613,165 (92.64%)

    Read length

    148.9 bp

    148.8 bp

    149.6 bp

    Total bases

    443,767,447

    174,694,261

    540,403,552

    Genome fraction

    0.11

    0.97

    1.00

    Avg. coverage

    0.15X

    62X

    117X

    Figure 3. Representative gDNA sequencing stats from three different organisms. Genomic DNA fragment libraries were generated using the NxSeq AmpFREE Low DNA Library Kit using 75 ng of sheared gDNA input from three organisms (human, Staphylococcus aureus, and Rhodobacter sphaeroides). The final libraries were quantitated and normalized to 2 nM final concentrations using the Bioanalyzer and Qubit fluorometer, and 5 µL of each library was run on a MiSeq using 2 x 150 bp chemistry and analyzed.


    Minimal Bias Detected

    NxSeq Fragment Library Kit Minimal Sequencing Bias

    Figure 4. Sequencing bias measured for three different organisms with varying GC content. DNA fragment libraries were generated from gDNA of three organisms with varying GC content (Staphylococcus aureus, 24% GC; E. coli K12, 50% GC; and Rhodobacter sphaeroides, 68% GC) according to the manufacturer’s recommended input amounts and protocols. Samples were quantitated using the Bioanalyzer and Qubit fluorometer and normalized to 2 nM final concentrations. Five µL of each library sample was sequenced on a MiSeq using 2 x 150 bp v2 chemistry and analyzed. Normalized coverage was calculated as the (average coverage of all windows with X% GC content) divided by the (overall average coverage).


    Don’t spend 25-74% More per Library with Another Kit

    Save Big with the NxSeq® AmpFREE Low DNA Library Kit

    PCR-Free Fragment Library Kit Cat. No. Size
    (rxns)
    2016 US
    List Price
    Cost/Reaction Per Rxn Cost Increase
    vs. NxSeq® Kit
    Lucigen NxSeq®
    AmpFREE Low
    DNA Library Kit
    14000-1 12 -- --
    14000-2 48 -- -- 12 rxn 48 rxn
    Kapa Hyper Prep Kit KK8501 8 -- -- +65% +74%
    KK8503 24 -- -- +45% +53%
    KK8505 96 -- -- +25% +32%

    Faster Protocol with Significantly Less Hands-on Time

    Save Time and Get Your Samples on the Sequencer Sooner!NxSeq Fragment Library Kit Fastest Protocol


    • Ordering

    • Manuals

    • Resources

    Contact your local distributor for pricing
    Product Description Size Cat. No.
    NxSeq® AmpFREE Low DNA Library Kit 12 rxns 14000-1
    48 rxns 14000-2
    NxSeq® Adaptors, Box 1 12 x 4 14300-1
    NxSeq® Adaptors, Box 2 12 x 4 14400-1
    ORDER INFORMATION

    The NxSeq AmpFREE Low DNA Library Kit and Adaptors are only compatible with Illumina sequencers.

    Each NxSeq AmpFREE Low DNA Library Kit contains Enzyme Mix (EM), 2X Buffer (2XB), Ligase (LIG) and Elution Buffer (EB). Adaptors must be purchased separately.

    Each box of NxSeq Adaptors contains (12) different indexed Illumina-compatible adaptors with enough of each adapter for 4 library reactions. Box 1 contains adaptors 1-12 and Box 2 contains adapters 13-24.

    The product manual is available under the Manuals tab.

    欢迎您咨询订购北京中北林格科技发展有限公司代理的Lucigen全系列产品,

    Lucigen中国区一级代理北京中北林格科技发展有限公司

    010-88891086 www.bjzblg.com

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • AllPrep DNA/RNA 96 Kit

      immediate stabilization at room temperature. For tissues, the TissueRuptor and TissueLyser II provide fast disruption at low- to high-throughputs. The AllPrep DNA/RNA 96 Kit is intended for molecular biology applications. This product is neither intended

    • Dynabeads® Co-Immunoprecipitation Kit

      Dynabeads® Co-Immunoprecipitation Kit Magnet: e.g. DynaMag™-2  Mixer allowing rotation or tilting of tubes. Antibodies of your choice. 实验步骤           Day 1 1.        Weigh out the appropriate

    • Dynabeads® mRNA DIRECT Kit

      of tissue/ cell harvest. Dynabeads® mRNA DIRECT™ Kit protocols can be scaled up or down to suit specific sample source and quantity. Please see section "Sample Guidelines and Scaling" before preparing the sample, and for recommended bead and buffer volumes

    图标技术资料

    暂无技术资料 索取技术资料

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥3175.20
    北京中北林格科技发展有限公司
    2025年07月13日询价
    ¥16000
    苏州近岸蛋白质科技股份有限公司
    2025年07月14日询价
    ¥7150
    Proteintech中国公司
    2025年06月26日询价
    询价
    北京启衡星生物科技有限公司
    2025年12月22日询价
    ¥31730
    上海善然生物科技有限公司
    2025年06月30日询价
    NxSeq® AmpFREE Low DNA Library Kit
    ¥12184.83