血清负压过滤器

收藏
  • ¥2079
  • PALL
  • 美国
  • 4631
  • 2025年08月20日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 文献和实验
    • 技术资料
    • 供应商

      研卉生物

    • 规格

      10/pkg

    血清负压过滤器,灭菌独立包装

    Innovative Bottle-Top Filters for Fast Vacuum Filtration of 100 mL to 5 L of Aqueous Solutions

    • Filter faster. Supor® membrane provides high flow rates.
    • No need to constantly refill upper fluid reservoir.
    • Draws directly from the mixing reservoir.
    • Eliminates the possibility of contamination from transfer steps. Filters directly into the desired container.
    • Match filter to sample volume by choosing from two sizes.
    • Available built-in prefilter increases throughput of particulate-laden solutions such as serum-containing media.
    • Environmentally-friendly with minimal plastic waste.
    • Patented small design accepts a variety of collection vessels and reduces storage space and waste.
    • TA version available with tubing attached to each device for maximum convenience.
    • Gamma irradiated, eliminates potential contamination by EtO residuals.
    • Materials of Construction

    • Filter Media: Supor [hydrophilic polyethersulfone (PES)] membrane
    • Housing: Modified acrylic
    • Membrane Support Material: Polyester
    • Sinker Material: Glass-filled polyurethane elastomer
    • Inlet Tubing: Polyvinyl chloride (PVC) medical-grade tubing
    • Gasket Seal Material: Polyethylene
    • Pore Size

    • 0.1, 0.2, 0.45, and 0.8/0.2 μm
    • Effective Filtration Area

    • VacuCap 60 Devices: 30 cm2
    • VacuCap 90 Devices: 60 cm2
    • Typical Throughput

    • (RPMI + 10% newborn calf serum)
      VacuCap 60 Devices, 0.2 μm: 1 L
      VacuCap 90 Devices, 0.2 μm: 5 L
    • (RPMI + 10% calf serum)
      VacuCap 60 PF Devices: 500 mL
      VacuCap 90 PF Devices: 1 L
    • Collection Vessel

    • VacuCap 60 Devices: Can be used on receptacles with openings ranging from 2 - 5 cm (0.8 - 1.9 in.)
    • VacuCap 90 Devices: Can be used on receptacles with openings ranging from 2 - 6.5 cm (0.8 - 2.5 in.)
    • Warning: Collection vessels should be vacuum rated. Implosion may result.

      Typical Hold-Up Volume

    • Vacucap 60 Devices: 1.2 mL
    • VacuCap 90 Devices: 3.2 mL
    • Maximum Operating Temperature

    • 55 °C (131 °F)
    • Typical Water Flow Rate

    • mL/min at 25.4 cm Hg (10 in. Hg)
      VacuCap 60 Devices VacuCap 90 Devices
      0.1 µm: 50 0.1 µm: 100
      0.2 µm: 200 0.2 µm: 400
      0.45 µm: 280 0.45 µm: 560
      PF: 200 PF: 400
    • Recommended Vacuum

    • 38.1 cm Hg (15 in. Hg)
    • Endotoxin Level

    • < 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test
    • Biological Safety

    • Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>
    • Sterilization

    • Sterilized by gamma irradiation and individually packaged
    • Part Number Description Pkg
      VacuCap 60 Devices
      4631 0.1 µm, 60 mm, gamma-irradiated 10/pkg
      4632 0.2 µm, 60 mm, gamma-irradiated 10/pkg
      4634 0.45 µm, 60 mm, gamma-irradiated 10/pkg
      TA4632 0.2 µm, 60 mm (supplied with individually attached tubing for each filter device), gamma-irradiated 10/pkg
      VacuCap 60 PF Device
      4638 0.8/0.2 µm, 60 mm, gamma-irradiated 10/pkg
      VacuCap 90 Devices
      4621 0.1 µm, 90 mm, gamma-irradiated 10/pkg
      4622 0.2 µm, 90 mm, gamma-irradiated 10/pkg
      4624 0.45 µm, 90 mm, gamma-irradiated 10/pkg
      TA4622 0.2 µm, 90 mm (supplied with individually attached tubing for each filter device), gamma-irradiated 10/pkg
      VacuCap 90 PF Device
      4628 0.8/0.2 µm, 90 mm, gamma-irradiated 10/pkg
      Accessories and Replacement Parts
      4623 Feedline accessory kit 1/pkg
    产品细节图片1 VacuCap® & VacuCap PF Vacuum Filtration Devices 产品细节图片2

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • 如何选购生物安全柜(图)

      平均值应至少为0.5m/s。70%气体通过HEPA过滤器再循环至工作区,30%的气体通过排气口过滤排除。二级B型生物安全柜均为连接排气系统的安全柜。连接安全柜排气导管的风机连接紧急供应电源,目的在断电下仍可保持安全柜负压,以免危险气体泄漏如实验室。其前窗气流速度最小量或测量平均值应至少为0.5m/s(100fpm)。B1型70%气体通过排气口HEPA过滤器排除,30%的气体通过供气口HEPA过滤器再循环至工作区。B2型为100%全排型安全柜,无内部循环气流,可同时提供生物性和化学性的安全控制。三级

    • 生物安全柜简介(图)

      见参考文献,也可参考生产商的说明手册。 图8 Ⅱ 级B1型生物安全柜原理图 A:前开口;B:窗口;C:排风HEPA过滤器;D:供风HEPA过滤器; E:负压压力排风系统;F:风机;G:送风HEPA过滤器。 安全柜需要有与建筑物排风系统相连接的排风接口。 表9Ⅰ级、Ⅱ级以及Ⅲ 级生物安全柜之间的差异 (NA,不适用) a所有生物学污染的管道均为负压状态,或由负压的管道和压力通风系统围绕。Ⅲ级生物安全柜 Ⅲ级生物安全柜(图9)用于操作危险度4级的微生物材料,可以提供最好的个体

    • 生物安全柜采购指南

      安全柜前窗气流速度最小量或测量平均值应至少为0.38m/s。70%气体通过HEPA过滤器再循环至工作区,30%的气体通过排气口过滤排除。A2型安全柜前窗气流速度最小量或测量平均值应至少为0.5m/s。70%气体通过HEPA过滤器再循环至工作区,30%的气体通过排气口过滤排除。A2型安全柜的负压环绕污染区域的设计,阻止了柜内物质的泄漏。 二级B型生物安全柜均为连接排气系统的安全柜。连接安全柜排气导管的风机连接紧急供应电源,目的在断电下仍可保持安全柜负压,以免危险气体泄漏如实验室。其前窗气流速度最小