    清醒大鼠脑电图实时监测仪 NEU-12-CON+ Continuous EEG on Awake Rat 清醒大鼠脑电图实时监测仪 产品细节图片1清醒大鼠脑电图实时监测仪.pdf
    The system was designed for continuous monitoring of EEG signals of conscious rat and mouse. The set-up can be expanded from one to eight channels. Swivels keep the continuous electrical contact between the amplifiers and sensors. The EEG signals are measured by Experimetria Ltd.’s high quality CRS-EEG amplifier and recorded, stored and analyzed by our S.P.E.L Advanced Neurosys EEG data acquisition system. The computer system can be adjusted so that it switches on inly in a case when a significant change occurs in the EEG signal.

    The system can be equipped with stimulatiors. For the different stimulation methods Experimetria provides the appropriate electronics. Various stimulation possibilities are:
    • light
    • voice
    • electrical

    For electrical stimulation our first class ground free programmable stimulator is available.

    Optional infrared camera with picture processing computer system for continuous monitoring is available.

    The advantage of this system lays in its flexibility. Parallel with the EEG monitoring, as the primary function, the system can be expanded to a complete behavior monitoring system. Several different investigation set-ups can be constructed with the variation of the available accessories:
    • NEU-08-CON Conducta examination box and 8 channel software
    • NEU-08-CON-01 Digital video recorder 8 channel software module
    • NEU-08-CON-02 Digital video recorder camera and computer card with console
    • NEU-08-CON-03 Stimulation grid for electric stimulation
    • NEU-08-CON-04 “Mouse option” for rat examination box that enabling the rat box to use it mouse too
    • AMP-04-EXT Extra- and intracellular signal amplifier with head stage (2 channel)
    • SOFT-05-02-NEUR S.P.E.L. Advanced Neurosys EEG software for data acquisition and analysis
    • Swivel
    • Stative
    • Crown (EEG cranium sensor) (10 pcs/ package)
    • FAR-01-01 Faraday cage

    The modern and newly developed plexi glass cage has been designed on such a way that the animal may be housed in it for weeks. Additional advantage of the design is that the lower tray and grating are independently and easily accessible for cleaning.

    References:
    Year Title Journal Authors

    2004
    Comparison of the effect of subacute organophosphate exposure
    on the cortical and peripheral evoked activity in rats
    Pesticide Biochemistry and Physiology 79 (2004) 94–100 András Papp, László Pecze, Tünde Vezér

    2009
    Subacute intratracheal exposure of rats to manganese nanoparticles_ behavoiral electrophysiological and general toxicological effects Inhalation Toxicology,2009;21(S1):83-91 Leila Sárközi, Endre Horváth, Zoltán Kónya, Imre Kiricsi, Brigitta Szalay, Tünde Vezér, András Papp

    2009

    Functional neurotoxicity of Mn-containing nanoparticles in rats

    Ecotoxicol.Environ. Saf. (2010),doi:10.1016/j.ecoenv.2010.09.002
    Gábor Oszlanczia,
    Tünde Vezér, Leila Sarkozia, Endre Horvath,
    Zoltán Konyab,
    András Papp

    2010
    Metal deposition and functional neurotoxicity in rats after 3-6 weeks nasal exposure by two physicochemical forms of manganese
    Environmental Toxicology and Pharmacology 30 (2010) 121–126
    Gábor Oszlánczia, Tünde Vezéra, Leila Sárközia, Edina Horváth, Andrea Szabó, Endre Horváth, Zoltán Kónyab, András Papp

    2012
    General and Electrophysiological Toxic Effects of Manganese in Rats following Subacute Administration in Dissolved and Nanoparticle Form

    Scientific World Journal. 2012; 2012: 520632.
    Edina Horváth, Zsuzsanna Máté, Szabolcs Takács, Péter Pusztai, András Sápi, Zoltán Kónya,
    László Nagymajtényi,
    András Papp

    2014

    In vitro intrinsic optical imaging can be used for source determination in cortical slices
    EUROPEAN JOURNAL OF NEUROSCIENCE
    Volume 39, Issue 1, January 2014,
    Pages: 72–82

    Sándor Borbély, Csaba Körössy, Zoltán Somogyvári, Ildikó Világi

    2014
    In vitro intrinsic optical imaging can be used for source determination in cortical slices European Journal of Neuroscience,
    Vol.39, pp.72–82, 2014
    Sándor Borb, Csaba Korossy, Zsolt Somogyvári, Ildikó Világi


    SEN-14-EEG Implantable EEG sensor (fixed on skull)


    SEN-14 is part of the continuous EEG measurement on awake rat system (NEU-12). Placed on rats' skull and connected to the pre-amplifier through a commutator unit.

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    • 作者
    • 内容
    • 询问日期
    图标文献和实验
    相关实验
    • 打个盹可以激发创造力!Sci Adv:爱迪生的打盹小技巧被证实科学可行

      力之间的相关研究。 看来,下一次当你再遇到难题的时候,不妨手里也握住一个钢球,让自己小憩一会。当钢球落下时,就是你与顿悟时刻相遇的美妙时机了! 延伸阅读: 脑波(Brain waves):它是神经细胞之间传递信息时产生的生物电信号。早在 1929 年,德国精神科医师 Hence Berge 首次发表脑电波 (electroencephalogram, EEG)。脑波依照频率由低到高可分为五大类 [3]: 1. δ 波 :0.5 – 4 Hz,与我们深层次的放松和恢复性睡眠相关; 2. θ 波

    • 原来声音真的可以缓解疼痛,与这个因素有关!Science:中国科学家揭示背后的神经基础

      与音乐诱导的镇痛有关,但这些只是关联,需要在动物中更充分地探索和操纵回路,以识别所涉及的神经底物。 接下来,研究者探索了观察到的低信噪比声音诱导镇痛背后的神经回路。为了探索这种效应背后的大脑回路,研究人员使用腺相关病毒与荧光蛋白相结合来进行荧光示踪,实时监测清醒小鼠不同大脑区域的神经细胞活动。最终确定了从听觉皮层到丘脑的路线,该听觉皮层接收和处理有关声音的信息,丘脑充当来自身体的感觉信号(包括疼痛)的中继站。 图片来源:参考资料 [1] 抑制 ACxGlu→PO 和 ACxGlu→VP 回路

    • 神经外科手术的麻醉

      神经外科手术的麻醉 1 脑血流的调节 2 颅内顺应性曲线 一、生理学基础 (一)脑血流量(cbf) 1、脑组织的供血来自颈内动脉(67%)和椎动脉(33%)。脑静脉血进入静脉窦离开颅腔后,经颈内静脉到上腔静脉。在静息状态时,成人的脑血流量占心输出量的15%-20%,平均为57ml/100g.min。 2、脑血流量取决于脑灌注区(cpp)和脑血管阻力(cvr);而cpp为平均动脉压(map)与颅内压(icp)之差

    图标技术资料

    需要更多技术资料 索取更多技术资料

    资料下载:

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    询价
    北京津发科技股份有限公司
    2025年12月31日询价
    询价
    赞德仪器有限公司
    2026年01月05日询价
    询价
    武汉一鸿科技有限公司
    2026年01月06日询价
    ¥20000
    上海玉研科学仪器有限公司
    2026年01月06日询价
    $10000
    上海然哲仪器设备有限公司
    2026年01月05日询价
    清醒大鼠脑电图EEG实时监测
    询价