Human FGF-4 ELISA Kit

Human FGF-4 ELISA Kit

收藏
  • ¥3200
  • WKSUBIO
  • 不限
  • China
  • WK-SU00120
  • 2025年12月22日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 技术资料
    • 适应物种

      不限

    • 库存

      不限

    • 供应商

      瓦兰生物

    • 检测范围

      不限

    • 检测方法

      酶联免疫法

    • 应用

      科研单位

    • 标记物

    • 样本

      液体

    • 规格

      96T

    英文:Human FGF-4 ELISA Kit
    中文:人成纤维细胞生长因子4(FGF-4) ELISA试剂盒


    Human FGF-4 ELISA Kit
    For the quantitative in vitro determination of Human fibroblast growth factor-4 concentrations in
    serum - plasma - celiac fluid - tissue homogenate - body fluid



    FOR LABORATORY RESEARCH USE ONLY.
    NOT FOR USE IN DIAGNOSTIC PROCEDURES.


    This package insert must be read in its entirety before using this product.

    ELISA
    ENZYME LINKED IMMUNOSORBENT ASSAY


    INTENDED USE AND TEST PRINCIPLE
    This FGF-4 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of FGF-4 in the sample, this FGF-4 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus FGF-4 concentration. The concentration of FGF-4 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    SAMPLE COLLECTION AND STORAGES
    Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximately 2000×g. Remove serum and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles
    Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.
    Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.
    Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.

    MATERIALS REQUIRED BUT NOT SUPPLIED
    1. 37 ℃ incubator
    2. Standard microplate reader capable of measuring absorbance at 450 nm
    3. Precision pipettes, disposable pipette tips and Absorbent paper
    4. Distilled or deionized water

    REAGENTS PROVIDED
    All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

    Name 96 determinations 48 determinations
    Microelisa stripplate 12*8strips 12*4strips
    Standard(6 vial) 0.5ml/vial 0.5ml/vial
    Sample diluent 6.0ml 3.0ml
    HRP-Conjugate reagent 10.0ml 5.0ml
    20X Wash solution 25ml 15ml
    Chromogen Solution A 6.0ml 3.0ml
    Chromogen Solution B 6.0ml 3.0ml
    Stop Solution 6.0ml 3.0ml
    Closure plate membrane 2 2
    User manual 1 1
    Sealed bags 1 1
    Note:
    1. Standard concentration was followed by: 200、100、50、25、12.5、6.25pg/mL.
    2. If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

    PRECAUTIONS
    1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
    2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
    3. Do not use kit components beyond their expiration date.
    4. Use only deionized or distilled water to dilute reagents.
    5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
    6. Use fresh disposable pipette tips for each transfer to avoid contamination.
    7. Do not mix acid and sodium hypochlorite solutions.
    8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
    9. All samples should be disposed of in a manner that will inactivate viruses.
    10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
    11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
    12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
    13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

    REAGENT PREPARATION AND STORAGE
    Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

    ASSAY PROCEDURE
    1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.
    2. Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.
    3. Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.
    4. Wash the Microtiter Plate 4 times.
    Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.
    Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.
    5. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.
    6. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.
    7. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

    CALCULATION OF RESULTS
    1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
    2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
    3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
    4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
    5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
    6. Assay range: 6.25 pg/mL – 200 pg/mL.
    7. Sensitivity: The minimum detectable dose of Human FGF-4 is typically less than 1.0 pg/mL.
    8. Cross-reactivity: This assay recognizes recombinant and natural Human FGF-4. No significant cross-reactivity or interference was observed.
    9. Storage: 2-8℃ (Use frequently); six months (-20℃)。
    10. Standard curve



    FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!


    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。