相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 保存条件:
4°C
- 保质期:
12个月
- 英文名:
AccuGreen High Sensitivity dsDNA Quantitation Solution (100 assays) 31068-T
- 库存:
99
- 供应商:
Biotium
- CAS号:
1
The AccuGreen™ High Sensitivity dsDNA Quantitation Solution offers sensitive and selective detection of purified dsDNA samples. The assay has a linear detection range from 0.1 – 100 ng and is designed for use with handheld fluorometers such as the Qubit® fluorometers from Thermo Fisher. This solution does not come with a DNA standard; see the AccuGreen™ High Sensitivity Kit (31066), which comes with a calf thymus DNA standard and is equivalent to the Qubit® dsDNA HS Assay Kit.
Features
- Designed specifically for Thermo’s Qubit® fluorometer
- Linear range: 0.1-100 ng dsDNA
- Sample concentration range: 5 pg/uL to 100 ng/uL
- Green fluorescence emission
Kit Components
- AccuGreen™ Dye, 200X
- DNA Quantitation Buffer, 20X Concentrate*
*Note: In order to go green and save on packaging and shipping, we have changed from a 1X to a 20X buffer.
AccuGreen™ for the Qubit® fluorometer
The AccuGreen™ High Sensitivity dsDNA Quantitation Kit is designed for use with handheld fluorometers such as the Qubit® fluorometers from Thermo Fisher.
The linear range of the AccuGreen™ assay is 0.1 to 100 ng of DNA per tube. DNA samples with concentrations between 5 pg/uL and 100 ng/uL may be quantified using sample volumes between 1 and 20 uL (for example, 1 uL of 100 ng/uL is 100 ng total, and 20 uL of 5 pg/uL is 0.1 ng total, which will both fall within the linear range of the assay). If you use the most common sample volume of 10 uL, the starting sample concentration should be 10 pg/uL to 10 ng/uL.

Fluorescence-Based dsDNA Quantitation
AccuBlue®, AccuClear® and AccuGreen™ dsDNA quantitation assays allow precise quantitation of purified dsDNA samples across a wide range of concentrations and a variety of fluorescence detection instruments. Unlike absorbance-based nucleic acid quantitation, fluorescent DNA binding dyes are highly sensitive and selective for double-stranded DNA and provide a more accurate DNA concentration in the presence of contaminating RNA and other common contaminants including free nucleotides, protein, detergents and salts.
Biotium offers dsDNA quantitiation kits and solutions for different instruments and sample concentration ranges. See the table below and visit the DNA & RNA Quantitation Technology Page for details on our full line of dsDNA and RNA quantitation kits.
All DNA & RNA Quantitation Kits
| Kit | DNA or RNA |
Detection range (in assay)* |
Dye Ex/Em (nm) | Suggested instrument | Features |
|---|---|---|---|---|---|
| AccuGreen™ High Sensitivity DNA |
DNA | 0.1-100 ng | 502/523 | Qubit® fluorometer | Compare to the Qubit® dsDNA HS assay from Thermo Fisher |
| AccuGreen™ Broad Range DNA | DNA | 2-1000 ng | 500/530 | Qubit® fluorometer | Compare to the Qubit® dsDNA BR assay from Thermo Fisher Non-toxic & non-mutagentic DNA quantitation dye |
| AccuBlue® NextGen DNA | DNA | 1-3000 pg** | 468/507 | Fluorescence microplate reader | Most sensitive assay available for quantitation of precious or dilute samples Optimal for sensitive applications such as NGS or digital PCR |
| AccuClear® Ultra High Sensitivity DNA | DNA | 0.03-250 ng | 468/507 | Fluorescence microplate reader | Versatile kit with high sensitivity and wide linear range |
| AccuBlue® High Sensitivity DNA | DNA | 0.2-100 ng | 485/530 | Fluorescence microplate reader | Non-toxic & non-mutagentic DNA quantitation dye |
| AccuBlue® Broad Range DNA | DNA | 2-2000 ng | 350/460 | Fluorescence microplate reader | Broad linear range with blue fluorescence |
| AccuBlue® Broad Range RNA | RNA | 5-1000 ng | 650/670 | Fluorescence microplate reader or Qubit® fluorometer |
The widest linear range of available RNA quantitation kits Exceptional accuracy, sensitivity, and high RNA selectivity |
** AccuBlue® NextGen limit of detection is in the range of 1 pg to 5 pg depending on instrument sensitivity
AccuBlue and AccuClear are registered trademarks of Biotium, Inc. AccuBlue, AccuClear and AccuGreen technologies are covered by granted U.S. and international patents. Qubit is a registered trademark of Thermo Fisher Scientific.
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验)。仔细收集上清。检测细胞内的成份时,用 PBS ( PH7.2-7.4 )稀释细胞悬液,细胞浓度达到 100 万 /ml 左右。通过反复冻融,以使细胞破坏并放出细胞内成份。离心 20 分钟左右( 2000-3000 转 / 分)。仔细收集上清。保存过程中如有沉淀形成,应再次离心。 5. 组织标本:切割标本后,称取重量。加入一定量的 PBS , PH7.4 。用液氮迅速冷冻保存备用。标本融化后仍然保持 2-8℃ 的温度。加入一定量的 PBS ( PH7.4 ),用手工或匀浆器将标本匀浆
Nat Med:个体化肿瘤疫苗突破,特异性 T 细胞持续 4.5 年,患者存活率 100%
疫苗是人类健康的保护伞。在预防疾病方面,疫苗消灭了恐怖的天花,也大大降低了脊髓灰质炎、乙肝、结核、宫颈癌等疾病,为人类的健康做出了卓越的贡献。目前肆虐全球的新冠病毒疫情,随着疫苗的研制成功也即将被全面控制。 在治疗疾病方面,个体化肿瘤疫苗也显示出了巨大的潜力,已经在恶性黑色素瘤等肿瘤上显示出了良好的疗效。 然而,目前市场上并没有如 CAR-T 细胞、PD-1/PD-L1 单抗等「明星」疫苗产品,究其原因是肿瘤疫苗起效缓慢,在短期疗效评估方面(如 ORR、PFS 等)并不占优势。那么其长期疗效
HIV-1-Specific Cytotoxic T-Cell Assays
Cytotoxic T-cells (CTL) provide the basis of protective immunity in many viral infections by appearing early in the immune response and becoming involved with the elimination of virus by lysis of infected cells. A considerable











