P32放射自显影曝光时间 P32 Autoradiographic Exposure Times
互联网
1962
Optimal exposure times must be empirically determined, but the following intervals are offered as a guide. In these cases, radioactive decay was measured on a Ludlum model 3 survey meter with a 44-3 detector, where 1 mR/hour is approximately 2500 counts per minute.
For genomic DNA, cpm are usually at background. Expose a minimum of 4 days.
For cloned DNA, use the following chart to estimate exposure times:
For genomic DNA, cpm are usually at background. Expose a minimum of 4 days.
For cloned DNA, use the following chart to estimate exposure times:
CPM just above membrane | Exposure Time |
---|---|
< 0.2 K | Overnight |
0.5 K | 3-5 hours |
1 K | 30 minutes |
3 K | 20 minutes |
In the dark room, place a sheet of X-ray film on top of an intensifying screen, then place the hybridization membrane on top of the X-ray film facing the film. The hybridization membranes are pre-wrapped in cellophane. Close the film cassette, wrap it in foil to prevent spurious light leaks, label the outside and expose in a -70°C freezer.
来自Lab of Dr. Mark Barton Frank, Oklahoma Medical Research Foundation
http://omrf.ouhsc.edu/~frank/AUTORAD.html