Liquid Plate Sealer® can be used for stabilizing coated ELISA plates, immunochromatographic test strips (lateral flow assays), affinity chromatography columns, protein arrays and for similar applications. It is used as a coating stabilizer for industrial ELISA kit production.
Instructions for use
Liquid Plate Sealer® is ready-to-use. Liquid Plate Sealer® is used directly after blocking and washing. Liquid Plate Sealer® seals and stabilizes coated proteins and antibodies. In case of strong background we recommend using The Blocking Solution (article number 110) before sealing.
The microtiter plate or solid phase is incubated with Liquid Plate Sealer® and dried afterwards. This expands the shelf life of the coated molecules substantially to typically 1 to 3 years when stored cool and dry. The assay buffer or the specimen can be added directly onto the sealed plate (solid phase) for use in the assay. An additional washing step is not necessary.
Sealing:
1. Commonly used coating and blocking procedure for microtiter plate.
2. After blocking: Wash 3 times with 200-300 µL Washing Buffer without detergents (e.g. article no. 146 or 141).
3. Add 200 µL Liquid Plate Sealer® per well and incubate for 15-90 minutes at approx. 20-30°C. (Volume per well should be 50 µL more than the coating volume or minimum the same volume as the coating volume to ensure that the complete coated surface area is covered by Liquid Plate Sealer® .)
4. Remove Liquid Plate Sealer® by suction. You can remove residual buffer by tapping the plate on absorbent paper. Incubate the plate at 37°C until dryness. Incubation time is typically in between 60 to 120 minutes, depending on temperature, incubator type, number of plates in the incubator and the (active) air circulation in the incubator.
An alternative method is air drying of the plate at room temperature (RT). It has to be mentioned that the resulting shelf life (also dependent on the antibodies) can be shorter compared to drying in an incubator. After drying at RT, the plates can be stored in the fridge until their use.
5. Storage: Store the plate sealed in a pouch under dryness (with additional desiccant if necessary) at 2-8°C for up to 1-3 years.
or:
An alternative method is storage of the plate without a pouch in the fridge. The shelf life of the plate will be reduced to several months instead of years. We recommend sealing of the plate with an appropriate adhesive film. Thus influence of air humidity and contamination will be reduced during storage. This simple method is a good and often used option for plates prepared for use in the own laboratory.
Addition of desiccant and sealing in a pouch is not necessary in this alternative approach.
Specifications given regarding the shelf life of the sealed plate represent guidance values only. Longer shelf lives have been reported for some assays, but may not be true for others, thus requiring the testing of the shelf life of each individual assay by the user.
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
用户评价
暂无用户评价
文献和实验- Novel diagnostic ELISA test for discrimination between infections with Yersinia enterocolitica and Yersinia pseudotuberculosis
- Remarkable immunogenicity and protective efficacy of BBV152, an inactivated SARS-CoV-2 vaccine in rhesus macaques
- Accurate determination of soluble Axl by enzyme-linked immunosorbent assay
- Rapidly produced SAM® vaccine against H7N9 influenza is immunogenic in mice
- Crimean Congo hemorrhagic fever serosurvey in humans for identifying high-risk populations and high-risk areas in the endemic state of Gujarat, India
- Development of indigenous IgG ELISA for the detection of anti-SARS-CoV-2 IgG
- Fabrication of cell culture-derived influenza vaccine dissolvable microstructures and evaluation of immunogenicity in guinea pigs
- Kinetics of viral RNA, immunoglobulin-M & G antibodies in Kyasanur forest disease
- Construction of an Immunochromatographic Determination System for N1,N12‐diacetylspermine
- A hydrogel sensor-based microfluidic platform for the quantitative and multiplexed detection of fertility markers for point-of-care immunoassays
- Supercritical angle fluorescence immunoassay platform
- Photochemical inactivation of alpha‐and poxviruses
- Patients with immune-mediated inflammatory diseases receiving cytokine inhibitors have low prevalence of SARS-CoV-2 infection
- Fast and sensitive interferon-γ assay using supercritical angle fluorescence
- Immunogenicity and protective efficacy of BBV152: a whole virion inactivated SARS CoV-2 vaccine in the Syrian hamster model
CANDOR BIOSCIENCE: 关于ELISA板稳定性的技术探讨与比较
商业化试剂盒的早期,应考虑其稳定性。简单的方法,如使用BSA作为稳定剂,对包被捕获分子的稳定性没有显著影响,并且无法保持板的功能性(Fig.1a)。更有效的是自20世纪80年代以来诊断生产中使用的的糖或碳水化合物溶液。这些溶液能够在确保持续制冷的情况下充分维持包被板的稳定性,从而成为第一个真正的固相稳定剂。这种以糖为基础的稳定剂通常可保持板的保质期在一年的范围内,但在此期间质量略有下降是常见的。由德国CANDOR BIOSCIENCE提供的Liquid Plate Sealer®(Fig.1b),与碳水
ul反应体系,384孔板、96-well Fast Thermal Cycling plate采用20ul反应体系。 有需求者,联系18217697290
. Despite not all European vendors being open about this limitation, Liquid Plate Sealer® animal-free and other one-step solutions are outperformed by dedicated serology surface blockers like CANDOR’s PlateBlock™ in this respect (Fig. 3). Yet, as shown, the combination