产品封面图

Dynabeads™ MyOne™ Streptavidin

C1
收藏
  • ¥5702
  • Invitrogen
  • 65001
  • 2025年09月06日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 文献和实验
    • 技术资料
    • 英文名

      Dynabeads™ MyOne™ Streptavidin C1

    • 规格

      2ml

    Dynabeads™ MyOne™ Streptavidin C1

    描述

    Dynabeads® MyOne™ Streptavidin C1 are the gold standard for isolation and handling of biotinylated nucleic acids, antibodies, or other biotinylated ligands and targets. The very high binding affinity of the streptavidin-biotin interaction (Kd=10-15) is used in a vast number of applications. Benefits and features:

    • Direct and fast isolation of any biotinylated molecule
    • Flexible protocols with gentle and efficient liquid-phase reaction kinetics
    • Well suited for nucleic acid applications with extreme demands
    • Very low nonspecific binding of nucleotides and nucleic acids
    • Low nonspecific binding of small and negatively charged proteins
    • Their small but uniform size presents a high surface area per mg beads and a correspondingly high capacity for the target molecule
    • Low sedimention rate, yet a high iron content, ensuring rapid magnetic separation
    • Biomagnetic protocols are easily adapted to automated platforms
    • High batch-to-batch reproducibility, securing consistent results in your application
    • Production follows a validated process in compliance with cGMP for medical devices

    About Dynabeads® MyOne™ Streptavidin C1
    These uniform and superparamagnetic beads are 1 µm in diameter, with a monolayer, not a multilayer, of recombinant streptavidin covalently coupled to the surface. This leaves the vast majority of the biotin binding sites sterically available for binding, not only of free biotin, but also for binding of biotinylated ligands/targets. They are hydrophilic, negatively charged, and show rapid liquid-phase reaction kinetics. Their specific and defined surface allow for efficient capture, separation, and downstream handling. The streptavidin monolayer ensures negligible leakage, and the lack of excess adsorbed streptavidin ensures batch consistency and reproducibility of your results. The 1 µm Dynabeads® MyOne™ have a large surface area, high capacity, efficient magnetic pull and a slow sedimentation rate during incubation. Tailor-made for use in automated protocols where high throughput is crucial. The product holds high standards with respect to reproducibility (both within and between batches), and automation ability, and drives reliability for your results.

    Applications
    Over the past 15 years, Streptavidin-coupled Dynabeads® have been used and cited for a very wide variety of applications. Examples include direct/indirect isolation and downstream handling of nucleic acids, proteins/peptides and other target molecules. Ideal for sequence specific DNA/RNA capture in nucleic acid based diagnostics, specifically with samples with a high chaotropic salt concentration, immunoassays involving small biotinylated antigens and applications that are not compatible with BSA (these beads are not blocked with BSA). Easily adapted to automated processes. Did you know that Dynabeads® are employed on more than 25,000 routine IVD instruments worldwide?

    Binding capacity
    The size of the molecule and the biotinylation procedure will affect the binding capacity. The capacity also depends on steric availability and charge interaction between bead and molecule and between molecules. There are two or three biotin binding sites available for each streptavidin molecule on the surface of the bead after immobilization. One mg of Dynabeads® MyOne™ Streptavidin C1 typically binds:

    • >2,500 pmoles free biotin
    • ~20 µg biotinylated IgG
    • ~400 pmol biotinylated peptides
    • ~20 µg ds-DNA
    • ~500 pmol ss-oligonucleotides

    规格

    Ligand Type: Streptavidin
    Bead Diameter: 1 µm
    Binding Property: >2,500 pmoles/mg beads
    Concentration: 10 mg⁄ml
    Form: Beads in Suspension
    High Throughput Compatibility: High Throughput-Compatible
    Iron Content (Ferrites): 26%
    Isoelectric Point: pH 5.2
    Product Line: DYNAL®, Dynabeads®, MyOne™
    Product Size: 2 mL
    Sample Type (Specific): Any Sample Type
    Size Distribution: CV < 5%
    Surface Functionality: Carboxylic Acid, Hydrophilic
    Shipping Condition: Room Temperature

    内容及储存

    Dynabeads® are supplied in PBS, pH 7.4 with 0.01% Tween®-20 and 0.09% NaN3. Store at 2-8°C

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • 寻找KO的阳性克隆——Cruiser

      近年来,ZFN、TALEN、CRISPR/Cas9等基因组编辑技术可谓是层出不穷,尤其是CRISPR/Cas9,一出现便在全球范围内掀起一股热潮。同时,各大公司也开发出一系列相应的产品,其中一种至关重要的就是基因敲除阳性克隆筛选的试剂。 目前,市面上只有Genloci的Cruiser、Transgenomic的SURVEYOR和NEB的T7EI这三种产品和测序这种方法,被用于基因敲除阳性克隆的筛选。然而,SURVEYOR是进口产品,价格贵,货期长;T7EI可以识别多种DNA结构,如十字

    • NEB 发布:GenomONE 为诱导 iPSC 形成「保驾护航」

      间充质干细胞(MSC, mesenchymal stem cells)是干细胞家族的重要成员,属于多能干细胞,因其具有多向分化潜能、造血支持和促进干细胞植入、免疫调控和自我复制等特点而日益受到人们的关注。诱导性多能性的间充质干细胞(iPMSCs)是药物筛选、再生医学和细胞治疗的新型候选药物。然而,用于生成骨髓间充质干细胞的诱导性多能性间充质干细胞(iPSC),在导入编码基因的转录因子中,往往伴随有在靶细胞基因组的插入时发生突变的风险。 由于近年来对骨髓间充质干细胞认知地深入,在造血系统、免疫

    • TetraOne KO:基因敲除技术的重大突破

      近日,赛业生物科技(Cyagen Biosciences)宣布推出其全球专利技术TetraOneTM KO,一种不仅在速度上媲美TALEN、CRISPR/Cas9(把ES打靶基因敲除/敲入鼠的定制周期降低至6个月),而且避免了TALEN、CRISPR/Cas9脱靶效应困扰的革命性技术。TetraOneTM KO的出现,是ES打靶技术制备基因敲除鼠的一个重大突破。基因组编辑的技术进展传统ES打靶、TALEN和CRISPR/Cas9是基因组编辑的三大技术及主要工具。新一代核酸酶基因编辑技术

    图标技术资料

    暂无技术资料 索取技术资料

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥680
    苏州海狸生物医学工程有限公司
    2026年01月03日询价
    ¥860
    天根生化科技(北京)有限公司
    2026年01月06日询价
    询价
    贝克曼库尔特国际贸易(上海)有限公司
    2026年01月06日询价
    询价
    上海吉玛制药技术有限公司
    2026年01月05日询价
    Dynabeads™ MyOne™ Streptavidin C1
    ¥5702