相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 样本:
血清/血浆/组织匀浆液
- 库存:
1000
- 适应物种:
Rat
- 应用:
科研使用
- 检测方法:
ELISA
- 检测范围:
31.25 - 2000 pg/ml
- 供应商:
康朗生物
- 规格:
96T
Performance 100% Guaranteed
Print This Page
Technical Help
Review This Product
SpecificationsPublicationsReviewsImages
Popular Carboxylesterase 1 / CES1 Elisa Kits
Human Carboxylesterase 1 / CES1 ELISA Kit (Sandwich ELISA) - LS-F25366
Reactivity: Human
Range: 0.156-10 ng/ml
Human Carboxylesterase 1 / CES1 ELISA Kit (Sandwich ELISA) - LS-F49884
Reactivity: Human
Range: 28.67-7000 pg/ml
Product Description
LS-F7737 is a 96-well enzyme-linked immunosorbent assay (ELISA) for the Quantitative detection of Rat Carboxylesterase 1 / CES1 in samples of Plasma, Serum and Tissue Homogenates. It is based upon a Sandwich assay principle and can be used to detect levels of Carboxylesterase 1 / CES1 as low as 14.1 picograms per milliliter.More Carboxylesterase 1 / CES1 Products
Top of Page
Specifications
TypeSandwich ELISA (enzyme-linked immunosorbent assay) kit
Target
Carboxylesterase 1 / CES1
Synonyms
CES1, ACAT, Brain carboxylesterase hBr1, Carboxylesterase 1, Carboxylesterase 2 (liver), CEH, CES1A1, CES1A2, Cocaine carboxylesterase, Egasyn, HMSE, Liver carboxylesterase 1, HCE-1, PCE-1, Retinyl ester hydrolase, TGH, Triacylglycerol hydrolase, REH, SES1, CE-1, Cholesteryl ester hydrolase, HMSE1, Serine esterase 1
Reactivity
Rat
Specificity
Carboxylesterase 1 (CES1) No significant cross-reactivity or interference between Carboxylesterase 1 (CES1) and analogs was observed.
Manual
Intended Sample Types
Plasma, Serum, Tissue Homogenates
Format
96-Well Strip Plate
Detection
Colorimetric - 450nm (TMB)
Measurement
Quantitative
Detection Range
31.25 - 2000 pg/ml
Sensitivity
14.1 pg/ml
Assay Time
4.5 h
Precision
Intra-Assay: CV<10% Inter-Assay: CV<12%
Storage
Short term: 4°C; Long term: see manual.
Quality Assurance
Due to their limited shelf life, LSBio ELISA kits are not typically stocked as finished goods. Upon receipt of an order each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Range, Sensitivity, and Precision. In the event of a significant change the order would be confirmed with the customer before shipping ELISA kit lot numbers reflect the date of final assembly and testing for each specific kit rather than a bulk manufactured lot. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
Kit Components
- Coated 96-well Strip Plate
- Adhesive Plate Sealers
- Standard (Lyophilized)
- Sample Diluent
- Detection Reagent A (Green)
- Detection Reagent B (Red)
- Assay Diluent A
- Assay Diluent B
- TMB Substrate
- Stop Solution
- Wash Buffer (30x concentrate)
Restrictions
For research use only.
Guarantee
This elisa kit carries the LSBio 100% Guarantee.
About Carboxylesterase 1 / CES1
Involved in the detoxification of xenobiotics and in the activation of ester and amide prodrugs. Hydrolyzes aromatic and aliphatic esters, but has no catalytic activity toward amides or a fatty acyl-CoA ester. Hydrolyzes the methyl ester group of cocaine to form benzoylecgonine. Catalyzes the transesterification of cocaine to form cocaethylene. Displays fatty acid ethyl ester synthase activity, catalyzing the ethyl esterification of oleic acid to ethyloleate.P23141 L07764 AAA16036.1
Top of Page
Publications (0)
Submit a Publication
Top of Page
Customer Reviews (0)
Submit a Review
Top of Page
Images
Sandwich ELISA Platform Overview
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验at 4°C for 15 minutes. 9. Remove and aliquot supernatant. We recommend making several 50 μl aliquots. 10. Before running ELISA, dilute protein 1:100 and run a Bradford total protein assay or Quant-iT™ Protein Quantitation Kit assay (Cat. no. Q
Clinical Chemistry and Other Laboratory Tests on Mouse Plasma or Serum
Parameters in Mouse Plasma Using the AU480 System Basic Protocol 4: Measurement of Mouse Osteocalcin by a Commercially Available Sandwich ELISA (Direct Detection) Basic Protocol 5: Measurement of Mouse/Rat PINP
Detection of apoptotic process in situ using immunocytochemical and TUNEL assays
during apoptosis. The tests were performed on sections of rat, chichen, frog and fish thymus. All the thymus were fixed in Bouin's fixative and embedded in paraffin wax (3). A) Immunocytochemical procedure The low molecular weight DNA fragments
技术资料暂无技术资料 索取技术资料










