    人乙肝e抗原(HbeAg) ELISA试剂盒

    S
    ample
    collection and storages

    Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles
    Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Note: The samples should be centrifugated adequately and no hemolysis or granule was allowed.
    Materials required but not supplied
    1. Standard microplate reader(450nm)
    2. Precision pipettes and Disposable pipette tips.
    3. 37 ℃ incubator
    Precautions
    1. Do not substitute reagents from one kit to another. Standard, conjugate and microplates are matched for optimal performance. Use only the reagents supplied by manufacturer.
    2. Do not remove microplate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
    3. Mix all reagents before using.
    Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C)
    Materials supplied
    Name 96 determinations 48 determinations
    Microelisa stripplate 12*8strips 12*4strips
    Standard 0.3ml 0.3ml
    Sample diluent 6.0ml 3.0ml
    HRP-Conjugate reagent 10.0ml 5.0ml
    20X Wash solution 25ml 15ml
    Chromogen Solution A 6.0ml 3.0ml
    Chromogen Solution B 6.0ml 3.0ml
    Stop Solution 6.0ml 3.0ml
    Closure plate membrane 2 2
    User manual 1 1
    Sealed bags 1 1
    Note: Standard concentration was followed by:
    201052.51.250 ng/mL.
    Reagent preparation
    20×wash solution:Dilute with Distilled or deionized water 1:20.
    Assay procedure
    1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.
    2. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.
    3. Add Sample: Add testing sample 10μl Then add sample diluent 40μl to testing sample well; Blank well doesnt add anyting.
    4. Add 10l of HRP-conjugate reagent to each well, cover with an adhesive strip and incubate for 60 minutes at 37°C.
    5. Aspirate each well and wash, repeating the process four times for a total of five washes. Wash by filling each well with Wash Solution (400μl) using a squirt bottle, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    6. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.
    7. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not


    appear uniform, gently tap the plate to ensure thorough mixing.
    8. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.
    Calculation of results
    1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
    2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
    3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
    4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
    5. The sensitivity by this assay is 0.1 ng/mL.
    6. Standard curve


    Storage2-8.
    validity six months.

    FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!
    Sample collection and storages
    Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles
    Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Note: The samples should be centrifugated adequately and no hemolysis or granule was allowed.
    Materials required but not supplied
    1. Standard microplate reader(450nm)
    2. Precision pipettes and Disposable pipette tips.
    3. 37 ℃ incubator
    Precautions
    1. Do not substitute reagents from one kit to another. Standard, conjugate and microplates are matched for optimal performance. Use only the reagents supplied by manufacturer.
    2. Do not remove microplate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
    3. Mix all reagents before using.
    Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C)
    Materials supplied
    Name 96 determinations 48 determinations
    Microelisa stripplate 12*8strips 12*4strips
    Standard 0.3ml 0.3ml
    Sample diluent 6.0ml 3.0ml
    HRP-Conjugate reagent 10.0ml 5.0ml
    20X Wash solution 25ml 15ml
    Chromogen Solution A 6.0ml 3.0ml
    Chromogen Solution B 6.0ml 3.0ml
    Stop Solution 6.0ml 3.0ml
    Closure plate membrane 2 2
    User manual 1 1
    Sealed bags 1 1
    Note: Standard concentration was followed by:
    201052.51.250 ng/mL.
    Reagent preparation
    20×wash solution:Dilute with Distilled or deionized water 1:20.
    Assay procedure
    1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.
    2. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.
    3. Add Sample: Add testing sample 10μl Then add sample diluent 40μl to testing sample well; Blank well doesnt add anyting.
    4. Add 10l of HRP-conjugate reagent to each well, cover with an adhesive strip and incubate for 60 minutes at 37°C.
    5. Aspirate each well and wash, repeating the process four times for a total of five washes. Wash by filling each well with Wash Solution (400μl) using a squirt bottle, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    6. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.
    7. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not


    appear uniform, gently tap the plate to ensure thorough mixing.
    8. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.
    Calculation of results
    1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
    2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
    3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
    4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
    5. The sensitivity by this assay is 0.1 ng/mL.
    6. Standard curve


    Storage2-8.
    validity six months.

    FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!
    Sample collection and storages
    Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles
    Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
    Note: The samples should be centrifugated adequately and no hemolysis or granule was allowed.
    Materials required but not supplied
    1. Standard microplate reader(450nm)
    2. Precision pipettes and Disposable pipette tips.
    3. 37 ℃ incubator
    Precautions
    1. Do not substitute reagents from one kit to another. Standard, conjugate and microplates are matched for optimal performance. Use only the reagents supplied by manufacturer.
    2. Do not remove microplate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
    3. Mix all reagents before using.
    Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C)
    Materials supplied
    Name 96 determinations 48 determinations
    Microelisa stripplate 12*8strips 12*4strips
    Standard 0.3ml 0.3ml
    Sample diluent 6.0ml 3.0ml
    HRP-Conjugate reagent 10.0ml 5.0ml

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    • 作者
    • 内容
    • 询问日期
    图标文献和实验
    相关实验
    • ELISA 中的抗原与抗体的反应

      (prezone),抗原过量称为后带(postzone)。在用免疫学方法测定抗原时,应使反应系统中有足够的抗体量,否则测得的量会小于实际含量,甚至出现假阴性。 3. 特异性 抗原抗体的结合实质上只发生在抗原的抗原决定簇与抗体的抗原结合位点之间。由于两者在化学结构和空间构型上呈互补关系,所以抗原抗体反应具有高度的特异性。例如乙肝病毒中的表面抗原( HBsAg)、e抗原(HBeAg)和核心抗原(HBcAg),随来源于同一病毒,但仅与其相应的抗体结合,而不与另外两种抗体反应。抗原抗体反应的这种

    • ELISA 原理与分类

      一、ELISA的原理 ELISA的基础是抗原或抗体的固相化及抗原或抗体的酶标记。结合在固相载体表面的抗原或抗体仍保持其免疫学活性,酶标记的抗原或抗体既保留其免疫学活性,又保留酶的活性。在测定时,受检标本(测定其中的抗体或抗原)与固相载体表面的抗原或抗体起反应。用洗涤的方法使固相载体上形成的抗原抗体复合物与液体中的其他物质分开。再加入酶标记的抗原或抗体,也通过反应而结合在固相载体上。此时固相上的酶量与标本中受检物质的量呈一定的比例。加入酶反应的底物后,底物被酶催化成为有色产物,产物的量与标本中

    • ELISA的原理和类型

      一、ELISA的原理ELISA的基础是抗原或抗体的固相化及抗原或抗体的酶标记。结合在固相载体表面的抗原或抗体仍保持其免疫学活性,酶标记的抗原或抗体既保留其免疫学活性,又保留酶的活性。在测定时,受检标本(测定其中的抗体或抗原)与固相载体表面的抗原或抗体起反应。用洗涤的方法使固相载体上形成的抗原抗体复合物与液体中的其他物质分开。再加入酶标记的抗原或抗体,也通过反应而结合在固相载体上。此时固相上的酶量与标本中受检物质的量呈一定的比例。加入酶反应的底物后,底物被酶催化成为有色产物,产物的量与标本中受检

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥3200
    上海瓦兰生物科技有限公司
    2026年01月16日询价
    ¥600
    上海钦诚生物科技有限公司
    2025年07月12日询价
    ¥1280
    温州科淼生物科技有限公司
    2025年07月12日询价
    询价
    深圳子科生物科技有限公司
    2025年09月12日询价
    询价
    深圳顺辰生物科技有限公司
    2026年01月15日询价
    人乙肝e抗原(HbeAg) ELISA试剂盒
    ¥3200