    抑制剂描述:

    产品名称:AST-1306 TsOH

    产品别名:见爱必信官网

    英文别名:AST-1306 TsOH

    靶点:EGFR

    CAS:1050500-29-2

    纯度:>98%

    外观:见爱必信官网

    保存方法:Store at -20℃ for one year(Powder);Store at 2-4℃ for two weeks;Store at -20℃ for six months after dissolution.

    描述:

    AST-1306是一种新型,不可逆的EGFR和ErbB2抑制剂,IC50分别为0.5 nM和3 nM,对突变型EGFR T790M/L858R也有效,作用于过表达ErbB2的细胞更有效,作用于ErbB家族比作用于其他激酶选择性高3000倍。AST-1306选择性抑制EGFR和ErbB2酪氨酸激酶活性。AST-1306也有效抑制T790M/L858R双突变型EGFR,IC50为12 nM。AST-1306效果比Lapatinib高500多倍。

    溶解性:DMSO :114 mg/mL (183.6 mM)

    体外研究:

    AST-1306 also ErB2 and EGFR T790M/L858R double mutant. AST-1306 is approximately 500-fold more potent than lapatinib and more than 3000-fold selective for ErbB family kinases over other kinase families including PDGFR, KDR and c-Met. AST-1306 might covalently bind to specific amino acid residues of EGFR and ErbB2. AST-1306 acts in a concentration dependent manner to significantly inhibit the growth of HIH3T3-EGFR T790M/L858R cells. AST-1306 effectively suppresses EGFR phosphorylation in HIH3T3-EGFR T790M/L858R cells. Moreover, AST-1306 blocks the growth of NCI-H1975 cells that harbor the EGFR T790M/L858R mutation in a concentration-dependent manner. AST-1306 blocks phosphorylation of EGFR and downstream pathways as well. In addition, AST-1306 dose-dependently and markedly inhibits EGF-induced EGFR phosphorylation in A549 cells. AST-1306 inhibits the phosphorylation of EGFR and ErbB2, and downstream signaling in human cancer cells including A549 cells, Calu-3 cells and SK-OV-3 cells.

    体内研究:Twice daily oral administration of AST-1306 gives rise to a dramatic prevention of tumor growth in SK-OV-3 and Calu-3 xenograft models. In SK-OV-3 models, tumors nearly disappears after treatment with AST-1306 for 7 days. In contrast, AST-1306 only slightly inhibits the growth of tumor in HO-8910 and A549 xenograft models. Therefore, the antitumor efficacy of AST-1306 is greater in ErbB2-overexpressing tumor models than in models expressing low levels of ErbB2. AST-1306 is well tolerated. Lapatinib displays antitumor activity in these ErbB2-overexpressing tumor models, but AST-1306 is more efficacious than lapatinib in the SK-OV-3 xenograft tumor model when given at the same dose and schedule. In addition, oral administration of AST-1306 twice daily for 3 weeks dramatically suppresses the growth of tumor in the FVB-2/Nneu models. After treatment for 11 days, tumors almost completely disappears. The body weights of the mice reduces by less than 20% during treatment.

    产品信息订购:

      产品货号   产品名称   规格 价格 大包装及货期
      abs816401   AST-1306 TsOH   5mg   1940.00   立即咨询
      abs816401   AST-1306 TsOH   10mg   2812.00   立即咨询
      abs816401   AST-1306 TsOH   25mg   4366.00   立即咨询

    产品更多信息请进入爱必信(absin)商城查看》》》



    absin,您身边的科研百宝箱
    专业提供试剂、耗材、仪器,在线订购,7*24h全国发货,方便快捷!

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • 肝脏血液检测――ALT & AST

      肝脏血液检测是最常见的血液检测,可用于评估肝脏功能或肝损伤。肝损伤检测的第一步是进行简单的血液检测,以确定血液中特定肝酶(蛋白质)的水平。目前临床上最敏感、应用最广泛的肝酶是转氨酶,包括门冬氨酸转氨酶(AST或 SGOT)和丙氨酸转氨酶 (ALT 或 SGPT)。这些酶主要存在于肝细胞内,一小部分存在于肌肉细胞内。如果肝脏受损或损坏,肝细胞中的转氨酶便进入血液,血液中ALT和AST水平升高,提示肝脏疾病信号。 其他有关的肝脏血液检测以肝脏中其他的酶类为指标。除了 AST 和 ALT

    • 全自动生化仪AST.ALT值不准的分析维修

      故障现象:一台BM717三年使用期,突然出现测试项目(AST,ALT)不准确。 常规分析:如果出现测试项目不准确或重复性不好,首先怀疑:     (1)Sample syning(样本注射器)的定量不准确,再排除Regent Syningl和Regent synin2(试剂注射器1和试剂注射器2)的定量不准确。换Sample syning和Regent syningl和Regent syning2的内密封垫,但故障依旧。     (2)怀疑灯泡不良,杯子析光度的值

    • 全自动生化分析仪测定ALT和AST结果失真的分析

      作者:张剑波 徐三男 龚国富  鄂州市中心医院(湖北鄂州436000) 【摘要】目的探讨用全自动生化分析仪测定ALT和AST结果失真的原因以及解决的方法。方法 全自动生化分析仪7600速率法检测ALT和AST。结果有一些ALT和AST测定结果太低甚至为负值,反应曲线异常,经过稀释后测定,其结果与稀释前相差甚远。结论遇到过低的结果要寻找原因,经常察看反应曲线,避免报告结果与临床不符。 【关键词】ALT AST 全自动生化分析仪速率法 血清丙氨酸氨基转移酶(ALT