Digital Image Comparison of Cellular Yield in Bronchial Brushing: Pre- and Post-Biopsy Lavage Cytology

作者信息Joshua Jing Xi Li, Joanna Ka Man Ng, Christopher Chan, Charlotte Ho Ying Lau, Joyce Ka Ching Ng, Rachel Lai Ping Lo, Wing Ho Yip, Jenny Chun Li Ngai, Ka Pang Chan
PMID38838662
期刊Acta Cytol
发布时间2024
DOI10.1159/000539567
查看来源

摘要

Introduction: Bronchoscopy is a useful diagnostic tool capable of performing core biopsy, forceps biopsy, bronchoalveolar lavage, and bronchial brushing. This study compares the cellularity of bronchial cytology including pre- and post-biopsy lavage by digital image analysis, aiming to increase diagnostic and tumor yield by optimizing the sequence and combination of bronchial biopsy and cytology. Methods: Alveolar macrophage, bronchial epithelium, and tumor cell cellularity from liquid-based cytology preparations of bronchial brushing and pre-biopsy and post-biopsy bronchoalveolar lavage were annotated on digitized whole-slide images and compared. Secondary analysis on the relationship of tumor cell and non-lesional cell yield was performed. Results: Overall, 118 cytology specimens from 43 patients were retrieved in total. Bronchial epithelium count was higher in pre-biopsy than post-biopsy lavage (p < 0.01) but not for alveolar macrophages nor tumor cell (p > 0.05). Tumor cell count was higher for bronchial brushing cytology samples than lavage (p = 0.018). The alveolar macrophage count was higher in post-biopsy lavage than bronchial brushing (p = 0.033); otherwise, brushing showed consistently higher bronchial epithelium and tumor cell counts. There were 33 false negative (tumor cell absent) specimens, and the combination of bronchial brushing and pre-biopsy lavage yielded the lowest false negative cases. Correlation between bronchial epithelium and alveolar macrophage counts with tumor cell count was weak (correlation coefficient = -0.168-0.203) except for post-biopsy lavage (correlation coefficient = 0.412-0.479, p < 0.05). Conclusion: Bronchial brushing yields a greater amount of tumor cell than lavage, and timing lavage before or after core biopsy does not affect tumor cell yield. Combining bronchial brushing and pre-biopsy lavage results in the lowest false negative rate.

实验方法

产品清单

名称品牌货号
细胞离心涂片机IV型Shandon, Life Science International [Europe] Limited--
徕卡AT2载玻片扫描仪LeicaAT2
QuPath软件--0.3.2
SPSS软件--23.0