ATIS 吹扫和捕集/增湿器模块
- ¥2073
- Merck
- 24937
- 2025年07月16日
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 库存:
999
- 现货状态:
现货
- 供应商:
洽姆
- 规格:
1件
| 货号 | 价格 | 名称 | 规格 |
| 20293 | 633.74 | 吹扫/捕集器 F, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 20294 | 633.74 | 吹扫/捕集器 E, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 20295 | 633.74 | 吹扫/捕集器 G, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 20308 | 1440.32 | Vocarb® 4000 吹扫/捕集器 I, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 21081 | 1673.20 | 吹扫/捕集器 G, for use with Dynatech "Dyna" | 1件 |
| 21143 | 1920.22 | Vocarb® 4000 吹扫/捕集器 I, for use with OI Analytical 4460 | 1件 |
| 24914 | 711.99 | 吹扫/捕集器 E, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24918 | 1282.60 | Vocarb® 4000 吹扫/捕集器 I, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24931 | 2054.56 | 吹扫/捕集器 B, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 24932 | 2072.28 | 吹扫/捕集器 C, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 24934 | 2014.42 | 吹扫/捕集器 E, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 24938 | 2085.73 | Vocarb® 4000 吹扫/捕集器 I, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 21066-U | 1407.40 | 吹扫/捕集 K Vocarb® 3000, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 21059-U | 619.27 | 吹扫/捕集器 A, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT3 | 1件 |
| 21062-U | 613.97 | 吹扫/捕集器 D, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 20321 | 1104.25 | 吹扫/捕集器 H, configured for Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 21064 | 1104.25 | 吹扫/捕集器 J BTEXTRAP™, for use with Tekmar® Velocity XPT, LSC-1, LSC-2, LSC-2000, 4000 (Straight, 12 in./30.5 cm, Swagelok fitting), HT-3 | 1件 |
| 20076-U | 1042.84 | 改进型 BTEXTRAP™ L,Tekmar® 2000 | 1件 |
| 20077-U | 1042.84 | 改进型 BTEXTRAP™ M,Tekmar® 2000 | 1件 |
| 21085-U | 1730.85 | 吹扫/捕集 K Vocarb® 3000, for use with Dynatech "Dyna" | 1件 |
| 21084 | 1711.66 | 吹扫/捕集器 J BTEXTRAP™, for use with Dynatech "Dyna" | 1件 |
| 20078-U | 1192.95 | 改进型 BTEXTRAP™ L,Tekmar® 3000 | 1件 |
| 20079-U | 1192.95 | 改进型 BTEXTRAP™ M,Tekmar® 3000 | 1件 |
| 21131-U | 1957.42 | 吹扫/捕集 K Vocarb® 3000, for use with OI Analytical 4460 | 1件 |
| 21135 | 1991.55 | 吹扫/捕集器 A, for use with OI Analytical 4460 | 1件 |
| 24913-U | 698.36 | 吹扫/捕集器 D, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24920-U | 1253.26 | 吹扫/捕集 K Vocarb® 3000, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24910-U | 697.71 | 吹扫/捕集器 A, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24917 | 1282.60 | 吹扫/捕集器 H, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24919 | 1282.60 | 吹扫/捕集器 J BTEXTRAP™, for use with Tekmar® 3000, 3100 (Straight, 12 in./30.5 cm, Valco fitting | 1件 |
| 24940-U | 2049.98 | 吹扫/捕集 K Vocarb® 3000, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 24930-U | 2036.75 | 吹扫/捕集器 A, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 24937 | 2072.28 | 吹扫/捕集器 H, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 24939 | 2085.73 | 吹扫/捕集器 J BTEXTRAP™, for use with OI Analytical Eclipse 4660, 4560 | 1件 |
| 21148 | 1191.77 | 吹扫捕集器 A,CDS, for use with CDS Peakmaster | 1件 |
| 21159 | 1159.01 | Vocarb® 3000 吹扫捕集器 K,CDS, for use with CDS Peakmaster | 1件 |
| 20080-U | 1095.14 | 吹扫/捕集 K Vocarb® 3000, for use with Encon | 1件 |
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验饮用水中有机物等。吹扫捕集样品浓缩器工作步骤: ①分析物的提取――②吹扫状态(用惰性气体吹扫样品溶液,将挥发性有机物携带至冷阱,被冷阱中预装的吸附剂吸附,以达到对挥发性有机化合物的浓缩目的)――③分析物的传送――④吸附及解吸状态(冷阱被快速的加热,使已吸附的化合物被解吸出来)――⑤送到GC进样口,完成色谱进样任务每一步骤的技术要点: ① 各种规格的自动进样器(根据实验需求选用):样品数量,自动识别固体液体,称重等功能 ② 吹扫是否需要加热:红外加热 ③ 传送管路惰性处理 ④ 吸附时要低温环境,解吸
美国O.I.顶空和吹扫捕集的特点 1.O.I 4632型顶空自动进样器的特点 a. 专利的取样环/阀设计(四通阀) b. 无样品传送线(阀上针),不影响手动进样。 c. 可编程序振荡 d. 磁性抓手 e. 编程导轨传送,可对两台GC4个进样口进样 f. 样品及阀可加热到1800C g. 32位样品取样 h. 可装在所有的GC上 I. 体积小(23”x16.8”x11.7”)重量轻(10kg) O.I.公司的顶空进样器与其它公司的设计相比,优点是废除了传统的传送
、确认载气流已通过色谱柱。把色谱柱的一端浸入盛有溶剂的瓶中,检查是否有气泡冒出。十、将色谱柱装入检测器中。查看仪器制造商手册以确定正确的插入深度。十一、检查是否存在泄漏。这点十分重要。在进行全面的泄漏检查之前不要将色谱柱加热。十二、设定适当的进样器和检测器温度。十三、设定适当的尾吹和检测器气流。点火或给打开检测器。十四、在室温下将色谱柱吹扫最少10分钟。维护进样口或捕集阱之后,应再吹扫一段时间。十五、注入非保留物质以检查进样器的安装是否正确。例如:丁烷或甲烷(FID)、乙腈的顶空气体(NPD)、二氯
技术资料暂无技术资料 索取技术资料