相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 保存条件:
常温
- 保质期:
根据瓶身LOT号查询
- 英文名:
Terbinafine hydrochloride
- 库存:
有现货
- 供应商:
浙江羽翔生物科技有限公司
- CAS号:
78628-80-5
- 规格:
100MG
属性
方案
≥98%
质量水平
200
表单
powder
颜色
white to faint beige
溶解性
methanol: soluble 50 mg/mL
抗生素抗菌谱
fungi
yeast
作用机制
enzyme | inhibits
SMILES字符串
Cl[H].[H]\C(CN(C)Cc1cccc2ccccc12)=C(\[H])C#CC(C)(C)C
InChI
1S/C21H25N.ClH/c1-21(2,3)15-8-5-9-16-22(4)17-19-13-10-12-18-11-6-7-14-20(18)19;/h5-7,9-14H,16-17H2,1-4H3;1H/b9-5+;
InChI key
BWMISRWJRUSYEX-SZKNIZGXSA-N
一般描述
应用
生化/生理作用
其他说明
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验An automated assessment system of limits of detection and quantitation in gradient high-performance liquid chromatography with ultraviolet detection.
A previous paper of this series of study put forward a basic model of an automated system for predicting detection limits and showed its application to a simple example of isocratic high-performance liquid chromatography (HPLC). This paper describes an expansion of the basic system into gradient HPLC. The most serious problem with the expansion is a long-term variation in backgrounds, called gradient baseline drifts, which in theory cannot be covered by a noise model (stationary random process) of the original system. This paper demonstrates that the above problem can be solved with modifying a parametrization procedure of the noise model. The essential role of the system is to predict the standard deviation (SD) of measurements at low concentrations from a chromatogram without repeated measurements of real samples. Laboratory-made software enables the automated assessment of the limits of detection and quantitation for each of chromatographically separated signals in a single run. Simulated background noise which consists of the stationary noise model with linear slopes is used to confirm the accuracy and reproducibility of the automated prediction. A gradient HPLC determination for cefaclor is taken as an example. The parametrization modification improves the correlation coefficient, r2, between the observed and theoretical distributions of the area measurements from 0.373 to 0.966. The statistical confidence levels of the theoretically predicted relative SDs for cefaclor were verified by comparing them with those obtained by repeated experiments (r2 = 0.989). The limits of detection (= 3.3 × SD = 18.0 µg/L) and quantitation (= 10 × SD = 54.7 µg/L) for cefaclor have signal-to-noise ratios close to the commonly adopted values, 3 and 10, respectively.
sorbitol buffer. The cells can be stored at this point overnight at 4¡C. Zymolyase treat the cells with 30 ul 10 mg/ml Zymolyase (100T) at 30¡C for anywhere between 10-30 min or more. Examine cells on a phase microscope. When cells are dark
treat the cells with 30 ul 10 mg/ml Zymolyase (100T) at 30¡C for anywhere between 10-30 min or more. Examine cells on a phase microscope. When cells are dark and mishapen, you have gone way too far, if bright and refractile they probably n eed
Yeast IF without Dehydration--酵母免疫荧光(无甲醇脱水方法)
) and once in the same buffer containing 1.2M sorbitol. Be very gentle with the cells! Resuspend in 0.5 mls sorbitol buffer. The cells can be stored at this point overnight at 4¡C. Zymolyase treat the cells with 30 ul 10 mg/ml Zymolyase (100T) at 30¡C
技术资料暂无技术资料 索取技术资料









