LS-F34627 is a 96-well enzyme-linked immunosorbent assay (ELISA) for the Quantitative detection of Human ECM1 in samples of Plasma, Serum and Tissue Homogenates. It is based upon a Sandwich assay principle and can be used to detect levels of ECM1 as low as 18.75 picograms per milliliter.
More ECM1 Products Top of Page
ECM1, Extracellular matrix protein 1, Secretory component p85
Reactivity
Human
Manual
Intended Sample Types
Plasma, Serum, Tissue Homogenates
Format
96-Well Strip Plate
Detection
Colorimetric - 450nm (TMB)
Measurement
Quantitative
Detection Range
31.25 - 2000 pg/ml
Sensitivity
18.75 pg/ml
Precision
Intra-Assay: CV<8% Inter-Assay: CV<10%
Storage
Store at 4°C. Stable for 6 months.
Quality Assurance
Due to their limited shelf life, LSBio ELISA kits are not typically stocked as finished goods. Upon receipt of an order each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Range, Sensitivity, and Precision. In the event of a significant change the order would be confirmed with the customer before shipping ELISA kit lot numbers reflect the date of final assembly and testing for each specific kit rather than a bulk manufactured lot. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
Kit Components
Adhesive Plate Sealers
Coated 96-well Strip Plate
Detection Antibody Diluent
Biotinylated Detection Antibody (100x)
HRP-Streptavidin Conjugate (100x)
HRP-Streptavidin Conjugate Diluent
Sample Diluent
TMB Substrate
Stop Solution
Wash Buffer (25x)
Standard (Lyophilized)
Background
This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti- ECM1antibody was pre-coated onto 96-well plates. And the biotin conjugated anti- ECM1 antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and wash with wash buffer. HRP- Streptavidin was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the ECM1 amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of ECM1 can be calculated.
Restrictions
ECM1 is a soluble protein that is involved in endochondral bone formation, angiogenesis, and tumor biology. It also interacts with a variety of extracellular and structural proteins, contributing to the maintenance of skin integrity and homeostasis. Mutations in this gene are associated with lipoid proteinosis disorder (also known as hyalinosis cutis et mucosae or Urbach-Wiethe disease) that is characterized by generalized thickening of skin, mucosae and certain viscera. Q16610NM_004425NP_004416.2