    Pyruvate Kinase A ELISA Kit (PKA), Human
     
    For quantitative detection in human samples.  (no photo available) 96 tests $975 KT-65739

    COMPONENTS
    Reagents Quantity
    Pre-coated, ready to use 96-well strip plate 1
    Calibrator 2
    Calibrator Diluent 1 × 20 mL
    Detection Reagent A 1 × 120 uL
    Detection Reagent B 1 × 120 uL
    Assay Diluent A 1 × 12 mL
    Assay Diluent B 1 × 12 mL
    TMB Substrate 1 × 9 mL
    Stop Solution 1 × 6 mL
    Wash Buffer (30X concentrate) 1 × 20 mL
    Plate sealer for 96 wells 4
    MATERIALS REQUIRED BUT NOT SUPPLIED
    1. Microplate reader with 450 ± 10 nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.a
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution. STORAGE All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon being received while the others should be at 4°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable for 1 month, provided it is stored as prescribed above.
    SAMPLE COLLECTION AND STORAGE
    Plasma
    Collect plasma using 3.8% sodium citrate (sodium citrate:blood = 1:9) as an anticoagulant. Centrifuge samples for 15 minutes at 1000 × g at 4°C within 30 minutes of collection. Remove plasma and assay immediately or store
    samples in aliquot at -20°C or -80°C for later use. Avoid repeated freeze/thaw cycles. Note:
    1. Samples to be used within 5 days may be stored at 4°C, otherwise samples must be stored at -20°C (≤1 month) or -80°C (≤2 months) to avoid loss of bioactivity and contamination.
    2. When performing the assay slowly bring samples to room temperature. 3. Sample hemolysis will influence the result, so hemolytic specimen can not be detected.
    REAGENT PREPARATION
    Bring all kit components and samples to room temperature (18-25°C) before use.
    产品细节图片1
    Detection Reagent A and B
    Briefly spin or centrifuge the stock Detection Reagent A and Detection Reagent B before use. Dilute to the working concentration with Assay Diluent A or B, respectively (1:100).
    Wash Solution
    Dilute 20 mL of Wash Solution concentrate (30X) with 580 mL of de-ionized or distilled water to prepare 600 mL of Wash Solution (1X).
    ASSAY PROCEDURE SUMMARY
    1. Prepare all reagents, samples and calibrators;
    2. Add 100 µL calibrator or sample to each well. Incubate 2 hours at 37°C;
    3. Add 100 µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100 µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 90 µL Substrate Solution. Incubate 15-25 minutes at 37°C;
    8. Add 50 µL Stop Solution. Read at 450 nm immediately.
    IMPORTANT NOTES
    1. The final experimental results will be closely related to operation skills of the end users and theexperimental environments. Please make sure that sufficient samples are available.
    2. Kits from different batches may be a little different in detection range, sensitivity and color developingtime. Please perform the experiment exactly according to the instruction attached in kit whileelectronic ones from our website (www.k-assay.com) is only for information.
    3. Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied bymanufacturer.
    4. Protect all reagents from strong light during storage and incubation. All the bottle caps of reagentsshould be covered tightly to prevent the evaporation and contamination of microorganism.
    5. There may be some foggy substance in the wells when the plate is opened at the first time. It will nothave any effect on the final assay results. Do not remove microtiter plate from the storage bag untilneeded.
    6. Wrong operations during the reagents preparation and loading, as well as incorrect parameter settingfor the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10 nmor less and an optical density range of 0-3 O.D. or greater at 450 ± 10 nm wavelength is acceptablefor use in absorbance measurement. Please read the instruction carefully and adjust the instrumentprior to the experiment.
    7. Even the same operator might get different results in two separate experiments. In order to get betterreproducible results, the operation of every step in the assay should be controlled. Furthermore, apreliminary experiment before assay for each batch is recommended.
    8. Each kit has been strictly passed Q.C. test. However, results from end users might be inconsistentwith our in-house data due to some unexpected transportation conditions or different lab equipments.
    Intra-assay variance among kits from different batches might arise from above factors, too.
    9. Kits from different manufacturers for the same item might produce different results, since we haven’tcompared our products with other manufacturers.
    10. The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, andclothing protection when using this material.
     

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标文献和实验
    相关实验
    • 【求助】PKC活性 ELISA试剂盒

      licanming 请问有无人用过assaydesigns公司的PKC Kinase Activity Assay Kit(cat NO:EKS-420A)?可否说一下应用的经验?注意事项等?还有,该试剂盒的说明书有几处地方不是很懂,请大家帮忙看一下: 1、To avoid cross contamination, change disposable pipette tips between the addition of each standard

    • MicroRNA Expression Profiling by Bead Array Technology in Human Tumor Cell Lines Treated with Interferon-Alpha-2a

      Assay (Invitrogen) as suggested by Illumina. Illumina Bead Array MicroRNA Detection Starting with 500 ng/sample of total RNA, mature microRNAs were amplified with the Illumina human v1 MicroRNA expression profiling kit containing primers for 743

    • 【求助】PKC激活程度测定

      磷酸化底物,而与非磷酸化底物无交叉反应。)检测残留在酶标板上的磷酸化底物。通过酶标二抗放大信号,读出OD值(蛋白激酶活性与OD值的对数成正比)。与对照组相比,得出处理组的蛋白激酶活性 (PKA, PKB, PKC, SGK, S6K和Tyrosine Kinase)等非放射性蛋白激酶分析测试盒http://www.immunechem.com 本文由丁香园论坛提供,想了解更多有用的、有意思的前沿资讯以及酷炫的实验方法的你,都可以成为师兄的好伙伴 师兄微

    图标技术资料

    暂无技术资料 索取技术资料

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    $543.75
    上海泽叶生物科技有限公司
    2025年07月07日询价
    $975
    上海钰博生物科技有限公司
    2025年07月15日询价
    ¥1650
    上海康朗生物科技有限公司
    2025年07月07日询价
    ¥500
    武汉纯度生物科技有限公司
    2025年06月17日询价
    询价
    深圳市科润达生物工程有限公司
    2025年12月24日询价
    Pyruvate Kinase A ELISA Kit (PKA), Human
    $975