相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 库存:
大量供应
- 供应商:
上海经科化学科技有限公司
- 现货状态:
询库存
- 保修期:
一年
货号:D3-000-024-R
注射速度:
|
充灌速度
|
Fast | 46 nL per second |
| Slow | 23 nL per second | |
| 注射速度 | Fast | 46 nL per second |
| Slow | 23 nL per second | |
| 倒空速度 | Fast | 230 nL per second |
| Slow | 92 nL per second |
Nanoject II Auto-Nanoliter Injector
- Automated microprocessor controlled Microinjection Pipet delivering precise nanoliter volumes accurately
- Remote control and non-rotating plunger eliminates vibration allowing precise injection minimizing possible cell rupture
- Selectable Injection Volumes: from 2.3 nanoliters to 69.0 nanoliters in 16 increments
- Selectable Operating Speeds:
Fill Speed Fast 46 nL per second Slow 23 nL per second Injection Speed Fast 46 nL per second Slow 23 nL per second Empty Speed Fast 230 nL per second Slow 92 nL per second - Supplied with sufficient borosilicate glass capillaries for preparing 400 injection tips, standard softening point 780°C
- Can be mounted on most micromanipulators
Note: Universal Adapter 3-000-024-A supplied with unit - Separate Foot Switch available to allow hands-free operation
Each Nanoject II Auto-Nanoliter Injector comes complete with 200 borosilicate capillaries that can be pulled to the required tolerance together with a back filling needle and maintenance kit.
Catalog Information
| Cat. No. | Description |
|---|---|
| 3-000-204 | Nanoject II Variable Volume (2.3 to 69 nL) Automatic Injector with Glass Capillaries (110V) |
| 3-000-205A | Nanoject II, 220V, CE, Euro |
| 3-000-206A | Nanoject II, 220V, CE, UK |
Note: Universal Adapter supplied with all the above units
Replacement Parts

| Cat. No. | Description |
|---|---|
| 3-000-002-KN | O-Ring kit for Models 204, 205A, and 206A includes: 1 collet, 1 small O-Ring, 1 spacer, 1 compression O-Ring, and 1 Allen wrench |
| 3-000-027 | 30 gauge, 2" Backfilling Needle |
| 3-000-000-203-X | Pointed Plunger Wire |
Replacement Glass Capillaries
| Cat. No. | O.D (mm) | Length | I.D. (mm) | Pack |
|---|---|---|---|---|
| 3-000-203-G/X | 1.14 | 3.5" | 0.53 | 100 |
| 3-000-203-G/XL | 1.14 | 7" | 0.53 | 100 |
This equipment is ready for use as received. It does require pulled capillary tips. It is essential that only the capillaries supplied or exact replacement capillaries are used for pulling micropipets.
Contents:
- a. Injector head with cord.
- b. Control box.
- c. Power supply with cord.
- d. Capillary glass; 2 vials of 100 pieces per vial:
1.( 3.5" capillaries, 100 pcs. (Cat. No. 3-000-203-G/X)
2.(7.0" capillaries, 100 pcs. (Cat. No. 3-000-203-G/XL)
- e. Replacement O-ring kit with collet, standard. (Cat. No. 3-000-002-KN)
- f. 1 Allen wrench for replacing wire plunger.
- g. 1 30g x 2" needle for backfilling pipets. Cat. No. 3-000-027
Operation:
The injector head should be mounted in a suitable micromanipulator or stereotaxic unit. Marzhauser model MM33 is quite suitable and frequently used. The aluminum barrel with the Drummond logo, provides an ideal clamping surface. Its diameter measures 11mm.The precise operation of the Nanoject II depends greatly on the use of tips prepared from the glass provided. We cannot guarantee that glass micropipets pulled from capillaries with other dimensions will work. Never attempt to use micropipets pulled from filament glass. Damage to the wire plunger will result and injection volumes will not be accurate.
Micropipet Pulling and Backfilling
The Nanoject II requires the use of pulled micropipets from the glass provided. Ideally, the tip size should be 10-30 microns in size. The capillary glass provided is produced from N-51-A material and has a softening point of 780º C. Many researchers pull the tips and then break them off with forcepts. This enables piercing the cell membrane much easier with no skipping. Once the tips are pulled, they must be "backfilled" with oil (or other non-compressible fluid) before attachment to the injector. Silicone or mineral oil is frequently used. Backfilling is facilitated by using the 30g x 2" needle and a syringe. Disposable spinal needles are also frequently used.
NOTE: THE NANOJECT II WILL NOT OPERATE PROPERLY WITHOUT BACKFILLING THE MICROPIPET.
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验SDS-聚丙烯酰胺凝胶电泳法测定蛋白质的分子量(垂直板型电泳)(图)
的,可以用SDS-凝胶电泳法测定其分子量。 SDS-PAGE有连续体系及不连续体系两种,这两种体系有各自的样品溶解液及缓冲液,但加样方式,电泳过程及固定、染色与脱色方法完全相同。三、器材与试剂: 1.器材: ①夹心式垂直板电泳槽,凝胶模(135×100×1.5mm)(北京六一仪器厂) ②直流稳压电源(电压300~600V,电流50~100mA) ③吸量管(1,5,10ml) ④烧杯(25,50,100ml) ⑤细长头的滴管
[ 仪器 与器械] 生物信号采集处理系统(或二道生理记录仪、前置放大器、示波器、水检压计、监听器)、压力换能器、张力换能器、引导电极、兔用手术器械一套、兔固定台、气管插管、胸内套管(或带橡皮管的粗穿刺针头)、20 ml注射器一个、微量注射器、50 cm长橡皮管、玻璃分针、橡皮膏、纱布、棉线。 [实验方法与步骤] 1. 麻醉和固定动物及气管插管: 方法同实验8.2 2. 呼吸
)、卵清蛋白(Mr 43 000)、血清白蛋白(Mr 67 000)等。按每种蛋白0.5-1mg/mL配制。可配成单一蛋白质标准液,也可配成混合蛋白质标准液。 二、器材 DYCZ-24D型垂直板电泳槽;移液管1 mL(′ 3),5 mL(′ 4),0.5mL(′ 1),0.1mL(′ 2);烧杯100mL(′ 2);细长头的吸管;微量注射器。 操作方法 一、 安装垂直板电泳
技术资料暂无技术资料 索取技术资料