相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 库存:
1000
- 供应商:
康朗生物
- 检测范围:
见说明书
- 检测方法:
酶联免疫
- 应用:
科研
- 标记物:
HRP标记物
- 样本:
血清/组织/尿液
Human ATP-citrate synthase(ACLY) ELISA kit
PRINCIPLE OF THE ASSAYThis assay employs the quantitative sandwich enzyme immunoassay technique.
Antibody specific for ACLY has been pre-coated onto a microplate. Standards
and samples are pipetted into the wells and any ACLY present is bound by the
immobilized antibody. After removing any unbound substances, a
biotin-conjugated antibody specific for ACLY is added to the wells. After washing,
avidin conjugated Horseradish Peroxidase (HRP) is added to the wells.
Following a wash to remove any unbound avidin-enzyme reagent, a substrate
solution is added to the wells and color develops in proportion to the amount of
ACLY bound in the initial step. The color development is stopped and the
intensity of the color is measured.
Human ATP-citrate synthase(ACLY) ELISA kit
DETECTION RANGE47 pg/ml-3000 pg/ml.
Human ATP-citrate synthase(ACLY) ELISA kit
SENSITIVITYThe minimum detectable dose of human ACLY is typically less than 11.75 pg/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as
the lowest protein concentration that could be differentiated from zero. It was
determined the mean O.D value of 20 replicates of the zero standard added by
their three standard deviations.
Human ATP-citrate synthase(ACLY) ELISA kit
SPECIFICITYThis assay has high sensitivity and excellent specificity for detection of human
ACLY. No significant cross-reactivity or interference between human ACLY and
analogues was observed.
Note: Limited by current skills and knowledge, it is impossible for us to complete
the cross-reactivity detection between human ACLY and all the analogues,
therefore, cross reaction may still exist. 3
PRECISION
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to
assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
LIMITATIONS OF THE PROCEDURE
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC
PROCEDURES.
The kit should not be used beyond the expiration date on the kit label.
Do not mix or substitute reagents with those from other lots or sources.
If samples generate values higher than the highest standard, dilute the
samples with Sample Diluent and repeat the assay.
Any variation in Sample Diluent, operator, pipetting technique, washing
technique, incubation time or temperature, and kit age can cause variation
in binding.
This assay is designed to eliminate interference by soluble receptors,
binding proteins, and other factors present in biological samples. Until all
factors have been tested in the Immunoassay, the possibility of
interference cannot be excluded.
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验licanming 请问有无人用过assaydesigns公司的PKC Kinase Activity Assay Kit(cat NO:EKS-420A)?可否说一下应用的经验?注意事项等?还有,该试剂盒的说明书有几处地方不是很懂,请大家帮忙看一下: 1、To avoid cross contamination, change disposable pipette tips between the addition of each standard
Analysis of Human Mitochondrial DNA Mutations
-cytochrome c oxidoreductase), three to Complex IV (cytochrome c oxidase or COX), and two to Complex V (ATP synthase). These subunits are synthesized within the mitochondrion, where they are assembled together with a larger number of subunits encoded
PriCells: Introduction of Isolation and Culture of Human Primary Hepatocytes
PriCells: Introduction of Isolation and Culture of Human Primary Hepatocytes The liver performs a wide range of physiologically important metabolic functions including the synthesis and secretion of albumin, fibrinogen, and other plasma proteins
技术资料暂无技术资料 索取技术资料






