Human Angiogenic factor with G patch and FHA domains 1(AGGF1) ELISA kit

Human Angiogenic factor with G

patch and FHA domains 1(AGGF1) ELISA kit
收藏
  • ¥1650 - 2680
  • KALANG
  • 见说明书
  • 美国/中国
  • KL-EL001444HU
  • 2025年07月11日
    avatar
  • 企业认证

    点击 QQ 联系

    • 详细信息
    • 技术资料
    • 库存

      1000

    • 供应商

      康朗生物

    • 检测范围

      见说明书

    • 检测方法

      酶联免疫

    • 应用

      科研

    • 标记物

      HRP标记物

    • 样本

      血清/组织/尿液

    Human Angiogenic factor with G patch and FHA domains 1(AGGF1) ELISA kitPRINCIPLE OF THE ASSAY
    This assay employs the quantitative sandwich enzyme immunoassay technique.
    Antibody specific for AGGF1 has been pre-coated onto a microplate. Standards
    and samples are pipetted into the wells and any AGGF1 present is bound by the
    immobilized antibody. After removing any unbound substances, a
    biotin-conjugated antibody specific for AGGF1 is added to the wells. After
    washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells.
    Following a wash to remove any unbound avidin-enzyme reagent, a substrate
    solution is added to the wells and color develops in proportion to the amount of
    AGGF1 bound in the initial step. The color development is stopped and the
    intensity of the color is measured.
    DETECTION RANGE
    0.312 ng/ml-20 ng/ml.
    Human Angiogenic factor with G patch and FHA domains 1(AGGF1) ELISA kitSENSITIVITY
    The minimum detectable dose of human AGGF1 is typically less than 0.078
    ng/ml.
    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as
    the lowest protein concentration that could be differentiated from zero. It was
    determined the mean O.D value of 20 replicates of the zero standard added by
    their three standard deviations.
    Human Angiogenic factor with G patch and FHA domains 1(AGGF1) ELISA kitSPECIFICITY
    This assay has high sensitivity and excellent specificity for detection of human
    AGGF1. No significant cross-reactivity or interference between human AGGF1
    and analogues was observed.
    Note: Limited by current skills and knowledge, it is impossible for us to complete
    the cross-reactivity detection between human AGGF1 and all the analogues,
    therefore, cross reaction may still exist.
    3
    Human Angiogenic factor with G patch and FHA domains 1(AGGF1) ELISA kitPRECISION
    Intra-assay Precision (Precision within an assay): CV%<8%
    Three samples of known concentration were tested twenty times on one plate to
    assess.
    Inter-assay Precision (Precision between assays): CV%<10%
    Three samples of known concentration were tested in twenty assays to assess.
    LIMITATIONS OF THE PROCEDURE
     FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC
    PROCEDURES.
     The kit should not be used beyond the expiration date on the kit label.
     Do not mix or substitute reagents with those from other lots or sources.
     If samples generate values higher than the highest standard, dilute the
    samples with Sample Diluent and repeat the assay.
     Any variation in Sample Diluent, operator, pipetting technique, washing
    technique, incubation time or temperature, and kit age can cause variation
    in binding.
     This assay is designed to eliminate interference by soluble receptors,
    binding proteins, and other factors present in biological samples. Until all
    factors have been tested in the Immunoassay, the possibility of
    interference cannot be excluded.

    风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

    图标技术资料

    暂无技术资料 索取技术资料

    同类产品报价

    产品名称
    产品价格
    公司名称
    报价日期
    ¥1650
    上海康朗生物科技有限公司
    2025年06月28日询价
    ¥4130
    上海冠东生物科技有限公司
    2025年11月18日询价
    $975
    上海钰博生物科技有限公司
    2025年06月25日询价
    ¥5300
    北京博蕾德生物科技有限公司
    2025年07月15日询价
    ¥3150
    上海研卉生物科技有限公司
    2025年07月15日询价
    Human Angiogenic factor with G patch and FHA domains 1(AGGF1) ELISA kit
    ¥1650 - 2680