相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 保存条件:
2-8°C
- 保质期:
根据瓶身LOT号查询
- 英文名:
Dextran from Leuconostoc mesenteroides
- 库存:
有现货
- 供应商:
浙江羽翔生物科技有限公司
- CAS号:
9004-54-0
- 规格:
10G
属性
生物来源
bacterial (Leuconostoc mesenteroides)
质量水平
200
表单
powder
旋光性
[α]/D 199°
分子量
average mol wt 9,000-11,000
溶解性
water: 0.1 g/mL, colorless to faintly yellow
储存温度
2-8°C
SMILES字符串
O1C(C(C(C(C1CO)O)O)O)OCC2OC(C(C(C2O)O)O)OCC(O)C(O)C(O)C(O)C=O
InChI
1S/C18H32O16/c19-1-5(21)9(23)10(24)6(22)3-31-17-16(30)14(28)12(26)8(34-17)4-32-18-15(29)13(27)11(25)7(2-20)33-18/h1,5-18,20-30H,2-4H2
InChI key
FZWBNHMXJMCXLU-UHFFFAOYSA-N
应用
小于60,000Da的葡聚糖通常被认为是低分子量葡聚糖。 低分子量葡聚糖的粘度、聚集和渗透性质使其通常优于高分子量葡聚糖。 高分子量、水溶性葡聚糖聚合物已可用于各种生物医学应用中。葡聚糖(9,000-11,000),是一种低分子量葡聚糖,可用于研究瞬时细胞膜和血脑屏障(BBB)透化等过程。在蛋白质包装和折叠研究中,它可以用作糖类拥挤剂。
制备说明
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验Comparison of contrast media and low-molecular-weight dextran for frequency-domain optical coherence tomography.
Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar. FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality.
技术资料暂无技术资料 索取技术资料