相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 供应商:
Cytiva
AcroPrep™ Advance 96-well filter plates for multiplexing, a Pall Life Sciences product, provide superior bead recovery and low levels of false positives to ensure assay reproducibility.
Smooth well wall provides efficient bead recovery, ensuring reproducible results lot after lot \nHigh performance membrane does not trap microspheres in the membrane matrix \nIn serological assays, Supor™ membrane effectively removes IgG complexes, thus reducing nonspecific reactivity of the microspheres and reducing false positives \nNew well design results in faster, more uniform filtration rates across the plate with reduced hold-up volume
New outlet tip geometry minimizes sample leakage and loss during incubation steps so that acquisition times are not affected \nIntrinsic plate and membrane properties minimize target loss from non-specific binding
Specifications
Materials of Construction
Filter Media: PP/PE non-woven (polypropylene/polyethylene) and Supor™(polyethersulfone) membrane Plate Housing: Polyproylene Lid: Polystyrene
Dimensions
Length: 12.8 cm (5.0 in.) Width: 8.6 cm (3.4 in.) Height With Lid: 1.8 cm (0.7 in.) Height Without Lid: 350 μL, 1.4 cm (0.6 in.)
Well-Bottom Area
0.25 cm2
Recommended Working Volume
350 μL: < 300 μL
Recommended Operating Vacuum
> 25.4 cm Hg (10 in. Hg)
Recommended Centrifugal Force
1,500 x g
Typical Processing Time
Vacuum: 2 seconds Centrifuge: < 2 minutes
Typical Hold-Up Volume
Vacuum: 5 μL Centrifuge: 3 μL
Applications
Bead-based multiplexing assays \nFlow cytometry
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验Nucleic Acid Programmable Protein Arrays: Versatile Tools for Array‐Based Functional Protein Studies
transformed with plasmid‐encoded proteins fused to affinity tag (T7 promoter‐based) (e.g., from the Center for Personalized Diagnostics of the Biodesign Institute at Arizona State University; 96‐well plates of bacterial glycerol stock
Question. Does anyone have a recipe for Saccomanno fixative (a cytology fixative) which gives the molecular weight of the Carbowax (polyethylene glycol) in the solution? Thanks in advance! Answer. This formula is from Koss. Roughly equal volumes
Transplantation Models to Characterize the Mechanisms of Stem Cell–Induced Islet Regeneration
‐well suspension plates (BD Falcon, cat. no. 351143) Hand tally counter (multi‐channel) for scoring colonies Collagen I–coated
技术资料暂无技术资料 索取技术资料