相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 技术资料
- 库存:
大量
- 供应商:
广州威佳科技有限公司
- 规格:
100ul
产品概况
| 货号 | M01272-3 |
|---|---|
| 产品名称 | Anti-GLS Antibody (monoclonal, 3G13) |
| 基因名 | GLS |
| 抗体来源 | Mouse |
| 克隆 | Monoclonal(Clone:3G13) |
| 抗体亚型 | Mouse IgG2a |
| 分子量 | 65-73KD |
| 免疫原 | E.coli-derived human Glutaminase/GLS recombinant protein (Position: K396-N654). |
| 内容 | 500 ug/ml antibody with PBS ,0.02% NaN3 , 1 mg BSA and 50% glycerol. |
| 纯化方式 | protein G purified. |
| 浓度 | 500 ug/ml |
| 产品形态 | Liquid |
| 保存条件 | 12 months from date of receipt,-20℃ as supplied. 6 months 2 to 8℃ after reconstitution. Avoid repeated freezing and thawing. |
| 背景资料 | This gene encodes the K-type mitochondrial glutaminase. The encoded protein is an phosphate-activated amidohydrolase that catalyzes the hydrolysis of glutamine to glutamate and ammonia. This protein is primarily expressed in the brain and kidney plays an essential role in generating energy for metabolism, synthesizing the brain neurotransmitter glutamate and maintaining acid-base balance in the kidney. Alternate splicing results in multiple transcript variants. |
| 研究类别 | 1. Lynch, D. S., Chelban, V., Vandrovcova, J., Pittman, A., Wood, N. W., Houlden, H. GLS loss of function causes autosomal recessive spastic ataxia and optic atrophy. Ann. Clin. Transl. Neurol. 5: 216-221, 2018.2. Modi, W. S., Pollock, D. D., Mock, B. A., Banner, C., Renauld, J.-C., Van Snick, J. Regional localization of the human glutaminase (GLS) and interleukin-9 (IL9) genes by in situ hybridization. Cytogenet. Cell Genet. 57: 114-116, 1991.3. Rumping, L., Tessadori, F., Pouwels, P. J. W., Vringer, E., Wijnen, J. P., Bhogal, A. A., Savelberg, S. M. C., Duran, K. J., Bakkers, M. J. G., Ramos, R. J. J., Schellekens, P. A. W., Kroes, H. Y., and 16 others. GLS hyperactivity causes glutamate excess, infantile cataract and profound developmental delay. Hum. Molec. Genet. 28: 96-104, 2019. |
| Uniprot ID | GLS: O94925 |
| 推荐配套的二抗和检测试剂 | Boster recommends Enhanced Chemiluminescent Kit with anti-Mouse IgG (EK1001) for Western blot, and HRP Conjugated anti-Mouse IgG Super Vision Assay Kit (SV0001-1) for IHC(P) and ICC. |
产品应用细节
为了提供优质的抗体,博士德对每一批抗体都用没有转染过的细胞系和体细胞组织检测,以保证博士德出品的抗体有足够的亲和性足以和对应蛋白天然的表达含量起反应。
| 应用 | 稀释度* |
|---|---|
| Western blot(WB): | 1:500-2000 |
| Immunohistochemistry in paraffin section (IHC): | 1:50-400 |
| Immunocytochemistry/Immunofluorescence (ICC/IF): | 1:50-400 |
| Flow cytometry (FCM): | 1-3μg/1x106 cells |
| (Boiling the paraffin sections in 10mM citrate buffer,pH6.0,or PH8.0 EDTA repair liquid for 20 mins is required for the staining of formalin/paraffin sections.) Optimal working dilutions must be determined by end user. | |
*稀释度需要用户自己调试,此处数据仅供参考。
**博士德提供高敏感的二抗和检测试剂盒。详情见相关产品推荐。
产品图片描述
点击图片放大
[list_product_images]Figure 1. Western blot analysis of anti- Glutaminase/GLS Antibody (M01272-3). The sample well of each lane was loaded with 50ug of sample under reducing conditions.
Lane 1: HepG2 whole cell lysates,
Lane 2: HEL whole cell lysates.
Use mouse anti- GLS 1:1000, probed with a goat anti- mouse IgG-HRP secondary antibody. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # EK1001). A specific band was detected for GLS at approximately 65-73KD. The expected band size for GLS is at 73KD.|Figure 2. Western blot analysis of anti- Glutaminase/GLS Antibody (M01272-3). The sample well of each lane was loaded with 50ug of sample under reducing conditions.
Lane 1: rat brain tissue lysates,
Lane 2: mouse brain tissue lysates.
Use mouse anti- GLS 1:1000, probed with a goat anti- mouse IgG-HRP secondary antibody. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # EK1001). A specific band was detected for GLS at approximately 65-73KD. The expected band size for GLS is at 73KD.|Figure 3. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human appendiceal adenocarcinoma tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 4. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human breast cancer tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 5. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human Gall bladder adenosquamous carcinoma tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 6. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human liver cancer tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 7. ICC analysis using anti- Glutaminase/GLS Antibody (M01272-2). was detected in immersion fixed SIHA cell. Cells were stained using the Dylight488-conjugated Anti-mouse IgG Secondary Antibody (green)(Catalog # BA1126) and counterstained with DAPI (blue). |Figure 8. Flow cytometry analysis of U937 cell (1x106) DyLight 488 conjugated goat anti-mouse IgG(blue) was used as secondary antibody. Isotype control antibody (Green line) was mouse IgG DyLight 488. Unlabelled sample (Red line).[/list_product_images]
Lane 1: HepG2 whole cell lysates,
Lane 2: HEL whole cell lysates.
Use mouse anti- GLS 1:1000, probed with a goat anti- mouse IgG-HRP secondary antibody. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # EK1001). A specific band was detected for GLS at approximately 65-73KD. The expected band size for GLS is at 73KD.|Figure 2. Western blot analysis of anti- Glutaminase/GLS Antibody (M01272-3). The sample well of each lane was loaded with 50ug of sample under reducing conditions.
Lane 1: rat brain tissue lysates,
Lane 2: mouse brain tissue lysates.
Use mouse anti- GLS 1:1000, probed with a goat anti- mouse IgG-HRP secondary antibody. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # EK1001). A specific band was detected for GLS at approximately 65-73KD. The expected band size for GLS is at 73KD.|Figure 3. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human appendiceal adenocarcinoma tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 4. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human breast cancer tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 5. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human Gall bladder adenosquamous carcinoma tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 6. IHC analysis using anti- Glutaminase/GLS Antibody (M01272-3). detected in paraffin-embedded section of human liver cancer tissue. Biotinylated goat anti-mouse IgG was used as secondary antibody. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # SA1021) with DAB as the chromogen.|Figure 7. ICC analysis using anti- Glutaminase/GLS Antibody (M01272-2). was detected in immersion fixed SIHA cell. Cells were stained using the Dylight488-conjugated Anti-mouse IgG Secondary Antibody (green)(Catalog # BA1126) and counterstained with DAPI (blue). |Figure 8. Flow cytometry analysis of U937 cell (1x106) DyLight 488 conjugated goat anti-mouse IgG(blue) was used as secondary antibody. Isotype control antibody (Green line) was mouse IgG DyLight 488. Unlabelled sample (Red line).[/list_product_images]
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
技术资料暂无技术资料 索取技术资料
Anti-Glutaminase/GLS Antibody (monoclonal, 3G13)(M01272-3-100ul)
¥1960







