相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 库存:
99
- 保修期:
按厂家质保
- 现货状态:
详询
- 供应商:
上海希言科学仪器有限公司
| 5191-4287 | 过滤器 | ValueLab filter Nylon 13mm 0.45um 100/pk |
| 5191-4290 | 过滤器 | ValueLab filter PTFE 13mm 0.2um 100/pk |
| 5191-4294 | 过滤器 | ValueLab fltr PTFE-Q 13mm 0.2um 100/pk |
| 5191-5851 | 泵油 | Agilent Vacuum Fluid 45 Platinum, 1Qt |
| 5200-0176 | 喷嘴 | FID Jet, universal fit, 0.011 inch ID |
| 5982-0101 | 反萃管 | Polish Tube-NaCl/MgSO4, 50/PK |
| 5982-1010 | 过滤柱 | QuEChERS dSPE EMR-Lipid |
| 5982-4432 | 过滤柱 | Carbon - Box, 50x 3 ml tubes, 250 mg |
| 5982-9313 | 陶制均质子 | Ceramic Homogenizers, 50ml tubes,100/pk |
| 6310001200 | 石墨管 | Graphite tubes, partitioned, 10/pk |
| 9301-0718 | 铝质瓶盖 | 20mm silver alum safety crimp cap 100pk |
| 9301-0719 | 塑料隔垫 | 20mm Tan PTFE/White silicone septa,100PK |
| 9301-0721 | 铝质瓶盖 | 20mm silver alum crimp cap,100pk |
| 9301-0722 | 样品瓶架 | 12mm Plastic vial rack, 5/PK |
| 9301-6524 | 溶剂瓶 | Solvent bottle clear, 1000ml |
| 9301-6526 | 溶剂瓶 | Solvent bottle amber, 1000ml |
| 9301-6528 | 溶剂瓶 | Solvent bottle clear, 1000ml with cap |
| CP17973 | 过滤器 | Gas Clean Filter Carrier Gas |
| G1099-20133 | 陶瓷绝缘体 | Repeller insulator |
| G1314-60100 | 长寿命氘灯 | D2 Lamp L6903 with Box |
| G1314-60101 | 长寿命氘灯 | Deuterium lamp w. RFID for VWD |
| G3440-81011 | 手拧柱螺帽 | Column Nut Assy, Finger Tight |
| G3440-81013 | 手拧柱螺帽 | Collared Column Nut, Self-Tightening MSD |
| G4513-80209 | 注射器 | Syringe 10ul straight, FN 23/42/HP |
| G7005-60061 | 离子源芯 | Filament,high temperature EI for GCMS |
| OT3-2 | 过滤管 | Trap, O2/H2O, 1/8in |
| RMSH-2 | 过滤管 | Big Universal Trap, 1/8inch fttgs,Helium |
| RMSN-2 | 过滤管 | Big Universal Trap, 1/8i fttgs, Nitrogen |
| X3760-64004 | 泵油 | AVF Platinum |
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验| 5191-4287 | 过滤器 | ValueLab filter Nylon 13mm 0.45um 100/pk |
| 5191-4290 | 过滤器 | ValueLab filter PTFE 13mm 0.2um 100/pk |
| 5191-4294 | 过滤器 | ValueLab fltr PTFE-Q 13mm 0.2um 100/pk |
| 5191-5851 | 泵油 | Agilent Vacuum Fluid 45 Platinum, 1Qt |
| 5200-0176 | 喷嘴 | FID Jet, universal fit, 0.011 inch ID |
| 5982-0101 | 反萃管 | Polish Tube-NaCl/MgSO4, 50/PK |
| 5982-1010 | 过滤柱 | QuEChERS dSPE EMR-Lipid |
| 5982-4432 | 过滤柱 | Carbon - Box, 50x 3 ml tubes, 250 mg |
| 5982-9313 | 陶制均质子 | Ceramic Homogenizers, 50ml tubes,100/pk |
| 6310001200 | 石墨管 | Graphite tubes, partitioned, 10/pk |
| 9301-0718 | 铝质瓶盖 | 20mm silver alum safety crimp cap 100pk |
| 9301-0719 | 塑料隔垫 | 20mm Tan PTFE/White silicone septa,100PK |
| 9301-0721 | 铝质瓶盖 | 20mm silver alum crimp cap,100pk |
| 9301-0722 | 样品瓶架 | 12mm Plastic vial rack, 5/PK |
| 9301-6524 | 溶剂瓶 | Solvent bottle clear, 1000ml |
| 9301-6526 | 溶剂瓶 | Solvent bottle amber, 1000ml |
| 9301-6528 | 溶剂瓶 | Solvent bottle clear, 1000ml with cap |
| CP17973 | 过滤器 | Gas Clean Filter Carrier Gas |
| G1099-20133 | 陶瓷绝缘体 | Repeller insulator |
| G1314-60100 | 长寿命氘灯 | D2 Lamp L6903 with Box |
| G1314-60101 | 长寿命氘灯 | Deuterium lamp w. RFID for VWD |
| G3440-81011 | 手拧柱螺帽 | Column Nut Assy, Finger Tight |
| G3440-81013 | 手拧柱螺帽 | Collared Column Nut, Self-Tightening MSD |
| G4513-80209 | 注射器 | Syringe 10ul straight, FN 23/42/HP |
| G7005-60061 | 离子源芯 | Filament,high temperature EI for GCMS |
| OT3-2 | 过滤管 | Trap, O2/H2O, 1/8in |
| RMSH-2 | 过滤管 | Big Universal Trap, 1/8inch fttgs,Helium |
| RMSN-2 | 过滤管 | Big Universal Trap, 1/8i fttgs, Nitrogen |
| X3760-64004 | 泵油 | AVF Platinum |
密封圈分别穿入捅针,在保持毛细管金属卡套套入石墨密封圈的状态下,用毛细管柱接头和毛细管螺母将毛细管石墨密封圈压紧成型,注意毛细管金属圈应保持平整,不能歪斜,否则易将毛细管柱割断。将定型后的毛细管密封圈分别穿入毛细管柱两头。检查毛细管柱头是否有污染现象,如柱头污染,必须将柱头被污染部分用毛细管割刀割去,切割时应保持毛细管切口平直。 在上述工作完成后,将毛细管柱插入汽化室的一端,石墨密封圈调整为离柱端40mm处,插入汽化室,用开口螺母固定拧紧,在开口螺母用手拧不动的状态下,再用扳手将开口螺帽扳紧1/4~
毛细管金属圈应保持平整,不能歪斜,否则易将毛细管柱割断。将定型后的毛细管密封圈分别穿入毛细管柱两头。检查毛细管柱头是否有污染现象,如柱头污染,必须将柱头被污染部分用毛细管割刀割去,切割时应保持毛细管切口平直。 在上述工作完成后,将毛细管柱插入汽化室的一端,石墨密封圈调整为离柱端40mm处,插入汽化室,用开口螺母固定拧紧,在开口螺母用手拧不动的状态下,再用扳手将开口螺帽扳紧1/4-1/2圈,汽化室端至毛细管柱安装完毕。开启载气,将毛细管柱柱前压调整至最佳柱前压,不同规格毛细管柱的柱前
密封损坏,造成压力波动;更换泵密封 d.系统存在漏液点;确定漏液位置并维修 f.柱后产生气泡;流通池出液口加负压调整器 g.检测器没有设定在最大吸收波长处;将波长调整至最大吸收波长处 h.柱平衡慢,特别是流动相发生变化时;用中等强度的溶剂进行冲洗,更改流动相时,在分析前用10-20倍体积的新流动相对柱子进行冲洗。 3、 接头处为何经常漏液,如何处理? 答:接头没有拧紧;拧松后再紧,手紧接头以手劲为限,不要使用工具,不锈钢接头先用手拧紧,再用专用