相关产品推荐更多 >
万千商家帮你免费找货
0 人在求购买到急需产品
- 详细信息
- 文献和实验
- 技术资料
- 保存条件:
-20°C
- 保质期:
1年
- 英文名:
Live-or-Dye™665/685 Fixable Viability Staining Kits,200 assays 32013
- 库存:
99
- 供应商:
Biotium
- CAS号:
1
Live-or-Dye™ Fixable Viability Staining Kits allow discrimination between live and dead cells by flow cytometry or microscopy. Live/dead stains are useful probes to include when analyzing cell surface protein expression by flow cytometry, because they allow intracellular fluorescence signal from dead cells with permeable plasma membranes to be excluded from analysis.
Features
- Highly dead-cell specific
- Covalent labeling with reactive dyes
- Withstand fixation and permeabilization
- Wide selection of colors
- Dye options designed for spectral flow
- Sampler kits for convenience
Single Color Kit Components
- Live-or-Dye™ fixable dead cell dye
- Anhydrous DMSO
Sampler Kit Components
- 5 different Live-or-Dye™ fixable dead cell dyes
- Anhydrous DMSO
Biotium offers a wide selection of Live-or-Dye™ viability stains spanning the fluorescence spectrum, for maximal flexibility in multi-color analysis. Visit the Live-or-Dye™ Technology Page for more data and information.
How It Works
Live-or-Dye™ Fixable Viability Stains are cell membrane impermeant amine-reactive dyes. The dyes are able to enter into dead cells that have compromised membrane integrity and covalently label free amines on intracellular proteins. The dye labeling is extremely stable, allowing the cells to be fixed and permeabilized without loss of fluorescence or dye transfer between cells. The Live-or-Dye™ staining protocol has been optimized to maximize live/dead discrimination with minimal live cell staining, in order to prevent interference with immunostaining.
Biotium has a wide selection of Live-or-Dye™ viability stains spanning the fluorescence spectrum (see Table 1 below), for maximal flexibility in designing multi-color flow panels.
We also offer two sampler kits, each containing five different dye colors, for excitation from all of the popular flow cytometry laser lines (see Table 2 below). The Live-or-Dye™ Sampler Kit, Standard (32016) was designed for use on the most common flow cytometer laser and filter configurations, with dyes excitable by UV, Violet, Blue, Yellow-Green, and Red lasers. The Live-or-Dye™ Sampler Kit, Spectral (32017) was designed for use in spectral scanning flow cytometry. It contains dyes excitable by UV, Violet, Blue, and Red lasers, all of which have been validated on the Cytek® Aurora spectral cytometer, and chosen for their ability to fill the gaps in many spectral flow panels.
Live-or-Dye™ Fixable Viability Stains are dead cell specific in all cell types, including mammalian cells, bacteria and yeast. See our Cellular Stains Table for more information on how our dyes stain various organisms.
Table 1: Single-Color Live-or-Dye™ Kits
Cat. No. |
Viability Dye |
Compatible lasers (nm) |
Optimal detection channels |
Notes |
|---|---|---|---|---|
| 32018, 32018-T | Live-or-Dye™ 330/410 | 355, 375 | BUV395 | |
| 32002, 32002-T | Live-or-Dye™ 350/448 | 355, 375 | DAPI | |
| 32014,32014-T | Live-or-Dye™ 375/600 | 355, 375, 405 | Spectral scan, BUV615, BV605 | Developed for spectral cytometry |
| 32003, 32003-T | Live-or-Dye™ 405/452 | 405 | Pacific Blue®, BV421, BV450 | |
| 32009, 32009-T | Live-or-Dye™ 405/545 | 405 | AmCyan, BV510 | |
| 32004, 32004-T | Live-or-Dye™ 488/515 | 488 | FITC | Validated for microscopy |
| 32012, 32012-T | Live-or-Dye™ 510/550 | 488, 532 | Spectral scan | Developed for spectral cytometry |
| 32005, 32005-T | Live-or-Dye™ 568/583 | 488, 532, 561 | PE, PI | Validated for microscopy |
| 32006, 32006-T | Live-or-Dye™ 594/614 | 488, 532, 561 | PI, PE-CF®594, PE-Texas Red® | Validated for microscopy |
| 32015, 32015-T | Live-or-Dye™ 615/740 | 633-640 | Spectral scan, APC-Cy®7 | Developed for spectral cytometry |
| 32007, 32007-T | Live-or-Dye™ 640/662 | 633-640 | APC | Validated for microscopy |
| 32013, 32013-T | Live-or-Dye™ 665/685 | 633-640 | Spectral scan, AF700 | Developed for spectral cytometry |
| 32008, 32008-T | Live-or-Dye™ 750/777 | 633-640, 785 | APC-Cy®7 | The brightest dye for the APC-Cy®7 channel |
| 32011, 32011-T | Live-or-Dye™ 787/808 | 785, 808 | APC-Cy®7, IR800 |
Table 2: Live-or-Dye™ Sampler Kits
Kit Name |
Catalog No. |
Included dyes: Ex/Em (Cat No.) |
Application |
|---|---|---|---|
| Live-or-Dye™ Fixable Viability Sampler Kit, Standard | 32016 | • 350/488 (32002A) • 405/545 (32009A) • 488/515 (32004A) • 568/583 (32005A) • 640/662 (32007A) |
Designed for use on most standard flow cytometry laser and filter configurations |
| Live-or-Dye™ Fixable Viability Sampler Kit, Spectral | 32017 | • 350/448 (32002A) • 375/600 (32014A) • 510/550 (32012A) • 615/740 (32015A) • 665/685 (32013A) |
Designed for use in spectral flow cytometry, to fill in gaps between common fluorophores |
风险提示:丁香通仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。
文献和实验,可以用于EMSA,Pull down,Enzyme activity assay等实验; 2.整个操作过程只需要一个小时左右; 3.即可以用于培养细胞(50x107个),有可以用于动物组织(50x200mg)蛋白质的提取; 4.避免蛋白酶对蛋白质的降解,保持蛋白质的完整性和天然活性; 5.可以同时处理多个样品。 编号 包装 价格 产地 BSP001 50 Assays 520 生工 wyj2002 好的
的研究,每次可以从107个培养细胞或200mg动物组织提取核蛋白质,本试剂盒可以使用50次。储存条件:2-~8℃ 产品特点: 1.提取的核蛋白质可以最大限度的保持蛋白质的活性,可以用于EMSA,转录因子分析的实验; 2.可以从50x107个培养细胞或50x200mg动物组织提取核蛋白; 3.整个实验过程只需要45分钟左右; 4.在提取的过程中,最大限度的减少了膜和胞质蛋白对核蛋白的污染; 5.不需要超速度离心,可以同时处理多个样品。 编号
细胞核蛋白质提取试剂盒 Nucleoprotein Protein Extraction Kit 产品说明:本试剂盒提供独特的组份,采用特殊的非离子型去污剂,以及焦磷酸钠等数种蛋白磷酸酶和蛋白酶抑制试剂,能够在非变性和低渗的条件下裂解细胞,经过洗涤去除大部分胞质蛋白和膜蛋白,释放的细胞核能够保持完整,再用Lysis Buffer对细胞核蛋白质进行抽提的同时可以保持核蛋白质的活性,因此该产品可合适用于SDS-PAGE电泳、Western Blot、免疫共沉淀,EMSA