Combined Subcutaneous Fat Aspirate and Skin Tru-Cut Biopsy for Amyloid Screening in Patients with Suspected Systemic Amyloidosis

作者信息Charlotte Toftmann Hansen, Hanne E H Møller, Aleksandra Maria Rojek, Niels Marcussen, Hans Christian Beck, Niels Abildgaard
PMID34203841
期刊Molecules
发布时间2021-06-15
DOI10.3390/molecules26123649
查看来源

摘要

Screening for systemic amyloidosis is typically carried out with abdominal fat aspirates with varying reported sensitivities. Fat aspirates are preferred for use in primary screening instead of organ biopsies as they are less invasive and thereby minimize the potential risk of complications. At Odense Amyloidosis Center, we performed a prospective study on whether the combined use of fat aspirate and tru-cut skin biopsy could increase the diagnostic sensitivity. Both fat aspirates and skin biopsies were screened with Congo Red staining, and positive biopsies were subsequently subtyped using immunoelectron microscopy and mass spectrometry. Seventy-six patients were included. In total, 24 patients had systemic amyloidosis (11 AL, 12 wtATTR, 1 AA), and 6 patients had localized amyloidosis. Combined fat aspirate and skin biopsy were Congo Red-positive in 15 patients (overall sensitivity (OS) 62.5%). Fat aspirates were positive in 14 patients (OS 58.3%), and the skin biopsy was positive in 5 patients (OS 20.8%). In only one patient did the skin biopsy add extra diagnostic information. The sensitivity differed between AL and ATTR amyloidosis-81.8% and 41.7%, respectively. Using skin biopsy as the only screening method is not recommended.

实验方法